The automated external defibrillator (AED) should be applied to individuals who are unresponsive and not breathing normally, as these signs may indicate a cardiac arrest. It is crucial to ensure the area is safe before applying the AED pads to the person's bare chest, following the device's audio and visual prompts. AEDs are designed for use by both trained and untrained bystanders, making them accessible in emergency situations. Always call emergency services before using an AED.
Use of the Automated External Defibrillator (AED)
An automated external defibrillator is a computerized device that charts heart rhythm. This medical device is portable and could tell you if you have cardiac arrhythmias.
An AED or Automated External Defibrillator is the professional name for a defibrillator. The device is used to shock the heart back into a normal rhythm, ultimately reviving the casualty. The device should be used in conjunction with CPR, and should never be used on a breathing individual.
You should only remove the automated external defibrillator (AED) pads from the victim after the AED has prompted you to do so, indicating that it is safe to remove them. This typically occurs after the device has analyzed the heart rhythm and delivered a shock if necessary. Additionally, the pads should remain in place if emergency medical personnel arrive and take over care. Always follow the specific instructions provided by the AED.
An automated external defibrillator (AED) should be used when the patient has cardiac arrest. This is when the heart suddenly stops beating; the AED will distribute a shock to the heart to try to get it beating again.
Here you can find good course about first aid-WeLearnTraining LLC Modules included in this course: 1 Basic Life Support & Safe Use of an Automated External Defibrillator 2 Emergency First Aid Work 3 Emergency First Aid Work, Defibrillation and CPR 4 Paediatric First Aid, the Safe Use of an Automated External Defibrillator & Managing illness & Injury 5 First Aid at Work and the safe use of an Automated External Defibrillator
Age doesn't matter. They should be more than 100 pounds. You should make sure they don't have a pacemaker or internal defibrillator. The AED will tell you everything you need to know step by step. Prior to placement you should make sure they are not wet or in water, have no chains or anything that can burn them, the area where the pads are being placed is free of hair (can burn them).
Age doesn't matter. They should be more than 100 pounds. You should make sure they don't have a pacemaker or internal defibrillator. The AED will tell you everything you need to know step by step. Prior to placement you should make sure they are not wet or in water, have no chains or anything that can burn them, the area where the pads are being placed is free of hair (can burn them).
There are specific companies that would stock automatic external defibrillators. Companies that stock these defibrillators would include AED Professionals.
You should keep following the voice prompts of the Automated External Defibrillator (AED). As a first aider, we cannot analyse an ECG and as such we cannot see the heart rhythm. Keep shocking and doing CPR until help arrives, the patient recovers or your safety becomes threatened (heatlh/exhaustion included).
When using an AED (Automated External Defibrillator), it's crucial to ensure that the environment is safe and that no one is touching the person receiving treatment during the shock delivery. Additionally, you should follow the audio and visual prompts provided by the AED, and ensure the pads are applied correctly to the patient's bare chest. It's also important to assess the patient's condition and call emergency services if they haven't been contacted already.
Yes, you should externally defibrillate a patient with a pacemaker who has gone into cardiac arrest. Chest compressions, rescue breathing and standard cardiac arrest procedures should be followed, while paying attention to the following points.EMS personnel should be aware that the pacemaker has its own implanted defibrillator and will fire charges at regular intervals. This should not harm the person doing chest compressions. A slight tingling feeling may be felt on the patient as the shock from the pacemaker is delivered. To avoid this, wear thick nitrile or latex gloves while doing chest compressions.The shock from the external defibrillator may cause damage to the pacemaker, and even interfere with it. To lessen the risk of this, the defibrillator should be placed on the lowest possible charge that is clinically accepted. If you notice that the implanted defibrillator and the external defibrillator both deliver a shock at the same time, standard procedure dictates that you wait 30 to 60 seconds prior to re-shocking with the external defibrillator. In the meantime, chest compressions and manual ventilation may be commenced.Intubation, artificial airways and other standard practices should be performed, despite the patient having a pacemaker.It is also vital that urgent medical help be called as with all cardiac arrest patients. Remember, cardiac arrest patients are not normally transported in the ambulance unless they are revived on scene.