When blowing down a boiler, the proper sequence is to first open the blow-off valve slowly to allow for a controlled release of pressure and water, followed by opening the blowdown valve. After the blowdown is complete, close the blowdown valve first, then close the blow-off valve. This sequence helps prevent potential damage and ensures safe operation by managing pressure changes effectively.

User Avatar

AnswerBot

2mo ago

What else can I help you with?

Related Questions

What is the mimimum distance for a window opening and a boiler flume?

A window opening is simply one of those topics that is vital, and that takes experienced ministership about


What safety measures should do by boiler tender during his watch?

The first and most important thing the operator must do at the start of his watch is to check the true water level in the boiler. This is done by first blowing down the water column, then blowing down the gage glass, remembering to close the gage cocks individually and reopening them to the proper position. Next he should check with the previous operator and check the log books for any known problems. Checking the safety valves, bottom blowing the boiler, testing chemistry of the water, checking safety cutoffs, and blowing soot off the tubes are all regular shift operations that must be done to maintain a safe operating condition of the boiler. Also, cleaning the boiler room is very important and shouldn't be overlooked, more operators are injured by slips and trips than any other hazard.


What to do if your furnace keeps blowing water out of the relief valve?

Nothing as a furnace is scorhed air a BOILER is either water or steam and "Relief Valves" are for liquid thus either you have a boiler or your furnace is being flooded from an outside source


Potterton puma combi boiler hot water ok but no heating why?

Solenoid valve on heating coil not opening or coil stopped up.


Define boiler and classification of boiler?

Boiler can be classified as below


What is mean by Blowing factor in steam blowing?

Disturbance Or Correction or K Factor in steam blowing in Power Plants is the ratio of Drag created during steam blowing to the drag occurring during Maximum Continuous Rating. Equation of disturbance factor K is shown as below: K=ΔP1/ΔP2 ΔP1=PD1-PS1;ΔP2=PD2-PS2 ΔP1:Difference pressure of steam drum and corresponding super heater during steam blowing-out. ΔP2: Difference pressure of steam drum and corresponding super heater in normal operation of boiler


Where is the girl in the boiler ROOM IN s.o.s island?

The boiler room is the room off of the ball room. During the third rescue, you must swim up through the ball room to get to the boiler room. To get inside, you need to make the hot water flow correctly through the pipes to the larger red pipe, and make it explode. Then you enter through the hole the explosion made. In the fourth rescue, the boiler room is the room that you enter directly through the opening in the ship. Hope this answer helped! ;)


What is afbc boiler?

Atmospheric Fluidized Bed Combustion Boiler (AFBC boiler) is a type of operational boiler. In a AFBC boiler a little more fluidized bed combustor is added than a conventional shell boiler.


How do you lightup afbc boiler?

what is boiler


What type of boiler should replace my Baxi Bermuda back boiler?

A system or combi boiler is a great replacement for a Baxi back boiler. Boiler Hut can help with selection and installation.


What is fish boiler?

A fish boiler is a hous boiler that stores fish instead of water.


How would you do an accumulation test in boilers?

An accumulation test in boilers is performed to assess the boiler's ability to handle sudden load changes without significant pressure drop. This involves rapidly closing the steam outlet valve while monitoring the pressure gauge to determine how quickly the boiler can recover to its set pressure. The test typically measures the boiler's response time and stability, ensuring it can maintain adequate steam pressure under varying operational conditions. The results help identify any potential issues with the boiler's performance and responsiveness.