Depending on the configuration of the pacemaker and the clinical needs of the patient, as many as three leads may be used in a pacing system.

User Avatar

Wiki User

14y ago

What else can I help you with?

Related Questions

What monitoring is done after a pacemaker has been implanted?

Once the procedure is complete, the patient's vital signs are monitored and a chest x ray is taken to ensure that the pacemaker and leads are properly positioned.


What complications occur with an old pacemaker leads left in a body after the pacemaker is replaced?

the answer is in the question. if the pacemaker is replaced the leads are used for it.


How do the procedures for temporary and permanent pacing systems differ?

The implantation procedure for the pacemaker leads is similar to that for a permanent pacing system, but the actual pacemaker unit housing the pulse generator remains outside the patient's body.


How do they connect a pacemaker to the heart?

A pacemaker is connected to the heart through one or more leads, which are thin, insulated wires. These leads are inserted through a vein and threaded into the heart, typically into the right atrium and/or ventricle. Once in place, the leads are attached to the pacemaker device, which is usually implanted under the skin, often in the chest area, to deliver electrical impulses that help regulate the heart's rhythm. The procedure is performed under local anesthesia and can be done using minimally invasive techniques.


Does slow heart rate require a pacemaker?

A slow heart rate, or bradycardia, may require a pacemaker if it causes symptoms such as dizziness, fatigue, or fainting, or if it leads to serious complications. The decision to implant a pacemaker depends on the underlying cause and severity of the bradycardia. If the heart rate is consistently low but not symptomatic, monitoring may be sufficient. Ultimately, a healthcare provider will assess the situation to determine the best course of action.


How are the wires of a pacemaker attached to the heart?

The wires of a pacemaker, known as leads, are attached to the heart by inserting them through a vein and guiding them to the heart chambers, typically the right atrium and ventricle. Once positioned, the leads are secured using small screws or tines that anchor them to the heart tissue. This allows the pacemaker to deliver electrical impulses effectively, helping to regulate the heart's rhythm. The procedure is usually done under local anesthesia and can be performed using minimally invasive techniques.


What does the term Oscar active fixation leads mean regarding radiology?

It should be Oscor active fixation leads. It refers to the leads of a pacemaker.


What kind of pacemaker has leads going to the right atrium and the left ventricle?

Dual.


What is the pacemaker made of?

A pacemaker is a small device, about the size of a wristwatch, that helps regulate the heart rate. The pacemaker is made of two main parts - the leads and the generator. The leads are thin wires that connect the heart with the generator. The leads can be attached to the surface of the heart or passed through a vein inside the heart. The lead is then attached to the generator. The generator is a small metal case that includes a battery and a microcomputer, which is the "brain" of the pacemaker. The generator is sutured under the skin in the upper chest or abdomen.


What is the name of the electrodes that are placed into the atrium and or ventricle of the heart when a pacemaker is inserted?

what is the name of the electrodes that are placed into the atrium and/or ventricle of the heart when a pacemaker is inserted? Leads l


What is the name of the electrodes that are placed into the atrium and ventricle of the heart when a pacemaker is inserted?

what is the name of the electrodes that are placed into the atrium and/or ventricle of the heart when a pacemaker is inserted? Leads l


What is codes for placement of a dual- chamber pacemaker placement only?

The codes for the placement of a dual-chamber pacemaker typically include CPT code 33208 for the insertion of a dual-chamber permanent pacemaker with leads. If the procedure involves additional components, such as generator replacement or lead placement, other codes may apply, such as 33206 or 33207. Always consult the latest coding guidelines and documentation for specific procedures and any updates in coding practices.