To fix an orange flame on your gas furnace, you should first check for any blockages in the burner or air intake. Clean or replace any dirty components. Adjust the air-to-gas ratio to ensure a blue flame, which indicates proper combustion. If the issue persists, contact a professional technician for further inspection and repairs.
yellow flame needs more air or cleaned orange flame could indicate moisture in the fuel if propane have your tank treated your L.P. dealer should be able to do this also I have seen this when people use hemidfers the orange is burnning of the minerals in the water
its hot!
The gas flame appears orange due to the presence of sodium particles in the gas, which emit a characteristic orange light when heated.
The function of a gas furnace flame sensor is to detect the presence of a flame in the furnace. It contributes to the proper operation of the heating system by ensuring that the gas valve remains open only when a flame is present, preventing the release of unburned gas and ensuring safe and efficient heating.
The furnace igniter may glow but not produce a flame due to issues such as a clogged burner, a faulty gas valve, or a malfunctioning flame sensor. These problems can prevent the gas from igniting properly, leading to the lack of a flame.
The pilot flame is/should be about 1.5" long, the diameter of a pencil. When the burners are going, the gas is shot into the burner manifold, and the gas sent to the burner is designed to go to the back of the heat exchanger. So, in a typical 80,000 input heater, about 14"-18" long.
A gas furnace pilot flame stays burning by receiving a constant flow of gas from the pilot light assembly. The pilot light assembly contains a thermocouple that detects the presence of the pilot flame. If the flame goes out, the thermocouple signals the gas valve to shut off, preventing any gas leaks.
If the furnace is direct ignition, The HSI or spark ignites the flame. A flame sensor passes current through the flame, if current is present the main.
The gas furnace pilot (flame is lit all the time) is sometimes referred to as a pilot light, but no matter what you call it, its purpose is to serve as a small ignition flame for the gas burner. And when this little flame fails to operate properly or go out, it's one of the most common reasons a gas furnace will fail to operate.
flame sensor
A furnace light blinking 4 times typically indicates an issue with the furnace's ignition system. This could be due to a faulty igniter, gas valve, or flame sensor. It is recommended to consult a professional HVAC technician to diagnose and fix the problem.
I'm assuming you mean the furnace? If the pilot light keeps going out on the furnace, you probably have a rusted through or cracked heat exchanger. Unfortunately the only way to fix the problem is to replace the furnace. IM THE ONE WHO ASKED THE QUESTIONN THIS IS NOT A FURNACE IT IS A GAS HEATER THAT HE PUT IN HIS DINNING ROOM