To troubleshoot and fix a malfunctioning furnace flame sensor, you can start by cleaning the sensor with fine sandpaper to remove any buildup. If that doesn't work, you may need to replace the sensor with a new one. Make sure to turn off the power to the furnace before attempting any repairs. If you're unsure or uncomfortable with these steps, it's best to contact a professional HVAC technician for assistance.
The furnace igniter may glow but not produce a flame due to issues such as a clogged burner, a faulty gas valve, or a malfunctioning flame sensor. These problems can prevent the gas from igniting properly, leading to the lack of a flame.
It tells the furnace that it lit... Hence the name Flame Sensor.
The flame sensor on a furnace is typically located near the burner assembly, usually positioned in the path of the flame.
The flame sensor on your furnace is typically located near the burner assembly, close to where the flame ignites. It is a small metal rod that detects the presence of a flame and signals the furnace to continue operating.
The furnace may ignite but shut off immediately due to issues with the flame sensor, gas supply, or a malfunctioning thermostat. It is important to have a professional inspect and repair the furnace to ensure safe and efficient operation.
Common symptoms of a furnace issue related to a bad flame sensor include the furnace not staying on, frequent cycling on and off, or the furnace not producing heat. Troubleshooting steps for this issue include cleaning the flame sensor with steel wool, checking the sensor's alignment, and ensuring the sensor is securely connected to the furnace.
turn the power source off for 5 to 10 minutes. and reboot , if it fails to run try again, if problem persists call a pro.
check your flame sensor
Your high efficiency furnace may shut off after the initial ignition due to issues such as a clogged air filter, a malfunctioning thermostat, or a problem with the flame sensor. It is important to have a professional technician inspect and repair the furnace to ensure it operates efficiently.
If the furnace is direct ignition, The HSI or spark ignites the flame. A flame sensor passes current through the flame, if current is present the main.
flame sensor
To troubleshoot a furnace that runs for 5 minutes and then shuts off, check the air filter for blockages, ensure the thermostat is set correctly, inspect the flame sensor for dirt or damage, and make sure the exhaust vent is clear. If the issue persists, contact a professional HVAC technician for further diagnosis and repair.