The recommended wire size for a 60A circuit is typically 6 AWG (American Wire Gauge) for copper wire.

User Avatar

AnswerBot

4mo ago

What else can I help you with?

Related Questions

What size wire for a welding extension cord 220v 50 amps?

For a 220V 50A welder, you would need a minimum of 6-gauge wire for your extension cord to ensure it can handle the current safely. It's recommended to use a heavy-duty, outdoor-rated extension cord with appropriate wire gauge and length to avoid voltage drop and overheating.


Can you use 10 2 wire to come off a 60A double throw and run it to a sub panel with 2 spaces 20A each and be up to residential code?

No, using 10-2 wire for a 60A circuit is not up to code. For a 60A circuit, you need to use at least 6 AWG copper or 4 AWG aluminum wire. Also, the subpanel should be sized appropriately for the amperage of the circuit it is fed from. In this case, the subpanel should be at least 60A, not 20A.


What size wire for 70 amps?

Use 6/3 Romex protected by a 60A breaker. You'll never miss the other 10A.


What size wire should be used to connect a 60A output from a generator to the distribution panel?

For a 60A output from a generator to a distribution panel, you would typically use a 6-gauge wire for copper or a 4-gauge wire for aluminum. Make sure to also check local electrical codes and guidelines to ensure correct sizing and safety compliance.


What is the purpose of a fuse in a mains circuit?

The main fuses protect the feeder lines from the electric company's feed to the main panel for the maximum ampacity rating of the wire. So depending on the size of the incoming tails nothing is gained by reducing the main supplier's cut-out fuse rating to 60A or 40A.


What size wire is legal for a 60A disconnect?

For a 60A disconnect, you should use a wire size of at least 6 AWG for copper conductors or 4 AWG for aluminum conductors. It is important to verify the specific requirements of the installation by consulting the National Electrical Code (NEC) or a qualified electrician.


Is a 60 amp breaker correct for a 10 kw 220 heat strip?

10 kW at 220v will use 45.45 Amps. I'd recommend a 60A circuit, with a 60A breaker, but the heater or electric furnace should have "maximum fuse amps" rated on its nameplate. Above all, neverconnect wiring to a breaker that is rated higher than the maximum current capacity of the wire. In the case of 60A, use #6 AWG wire.The HVAC Veteran


What is the maximum amperage capacity of a 60A breaker and how does it affect the electrical circuit it is protecting?

The maximum amperage capacity of a 60A breaker is 60 amps. This means it can handle up to 60 amps of electrical current before tripping and shutting off the circuit. It protects the electrical circuit by preventing an overload of current, which can cause overheating and potentially start a fire.


Is it unsafe to have 60A service going into a new electrical box designed for 100A?

Its not recommended because your new main breaker will allow up to 100 amps and your old wire can only safely handle 60amps. If you put a 60amp main breaker in the new box, that would be acceptable. No, it is perfectly safe. Because the box is overrated, there is no problem. If the box is the main panel, and not a subpanel, install a 60A main breaker so you cannot overload your service. If it is a subpanel this 60A breaker should be in the main panel.


What wire is required for a 60A sub panel off a 150A main service?

For a 60A sub panel, you would typically use 6 AWG copper wire or 4 AWG aluminum wire to connect it to a 150A main service. Make sure to consult local electrical codes and regulations to ensure compliance.


What is the short circuit capacity of a BS 1361 60A cartridge fuse?

The short circuit capacity of a BS 1361 60A cartridge fuse is typically around 6000A. This represents the maximum fault current that the fuse can safely interrupt without causing damage or posing a safety hazard. It is important to ensure that the short circuit capacity of the fuse matches or exceeds the available fault current in the circuit where it is being used.


Low voltage cable size calculation formula?

1) determine load /design current. eg 13kw oven Ib=13000W/230V if 3 phase- 13000w/1.73*400V =56.52A In(circuit breaker size)=60A 2) In/ C1+C2+C3 (c is coefficient of ambience temperature of type of cable referred to BS tables) 3) value of above refer to BS tables for appropiate cale size. eg. based on 60A cable size is 16mm2 pvc/pvc cable size