The GFCI may be tripping with no load connected due to a ground fault or a faulty GFCI outlet. A ground fault can occur if there is a leakage of electrical current to the ground, causing the GFCI to trip as a safety measure. It is recommended to have a qualified electrician inspect and troubleshoot the issue to ensure proper functioning of the GFCI outlet.
Because something is wrong. Check for shorts and, if it is a GFCI, also check for ground faults and leakages. It is also possible, in the case of a GFCI, that an inappropriate load, such as a computer monitor or UPS, is connected. These devices pull transient power to ground and will trip a GFCI. Do not ignore the situation. The protective device is tripping for a reason.
A 20 amp GFCI breaker may keep tripping due to a ground fault, overloading, or a faulty breaker. Check for any faulty appliances or wiring causing the ground fault, reduce the load on the circuit to prevent overloading, and consider replacing the breaker if it continues to trip.
A GFCI can trip with no load on it due to internal issues, such as a faulty wiring connection or a malfunctioning internal component. This can cause the GFCI to detect a ground fault even when there is no actual fault present, leading to the tripping of the device.
Is the GFCI wired correctly. Voltage in goes to LINE. Voltage out goes to LOAD. Ground wires connect together and connected to ground on GFCI. All screws tight. If all this is correct and you have no loose wires on any of the outlets and no wires are shorted out in any of the outlets then more than likely you have a defective GFCI. Replace it with another one. I get bad ones all the time.
The breaker may be tripping with no load due to a short circuit, ground fault, or overheating. These issues can cause the breaker to trip as a safety measure to prevent damage or fire.
The GFCI (Ground Fault Circuit Interrupter) can trip with no load due to internal issues or a ground fault in the circuit. This can happen if there is a problem with the wiring or if the GFCI itself is faulty.
Don't know what you mean by back wire, but most GFCI outlets have a circuit to attach additional outlets that will be protected by the GFCI. Keep total load in minds.
If you have contineous tripping on a breaker then there is a fault on the load of that breaker. Don't reset it any more. What is the breaker connected to?
Tripping of circuit breakers usually means they are overloaded, or that some load is faulting. This is a common problem in offices, as the personnel tend to add things to their outlets without coordinating with facilities engineering. If they are GFCI breakers they can also trip when a computer monitor powers up, because that causes a current transient to protective earth ground, causing the GFCI to think there is a ground fault.
First, lets say this: GFCI stands for Ground-Fault Circuit Interupter. This is NOT an over-current device, and NOT an over-load device. This device stop the flow at 6mA (6/1000 of an amp) of leakage current - current leaking to ground from either the hot or neutral wire. Do you mean a GFCI breaker or a GFCI receptacle?? GFCI receptacles do not "trip on overload". Period. The only over-current protection on a receptacle is provided by the circuit breaker protecting that branch circuit. GFCI breakers are ALSO over-current devices just like normal breakers. And yes, they DO get weak, just like standard breakers do from repeated tripping. They basically have a metal strip inside that gets bent and straightened each time you trip & reset the breaker. All metal gets weak when it gets bent & straightened repeatedly. It is called "metal fatigue".
Most probably the receptacles downstream from the GFCI would not be protected by the GFCI receptacle.
Yes, you can plug a power strip or surge protector into the GFCI outlet and then plug the fans into the strip. Just ensure that the total load of the fans does not exceed the capacity of the GFCI outlet to prevent overheating or tripping the circuit.