Backslash is a character on a keyboard. Backlash is the inherent slackness in the mechanical parts of a micrometer which allow an extremely small movement of the operating barrel without any corresponding movement of the measuring 'anvil' of the micrometer.

User Avatar

Wiki User

16y ago

What else can I help you with?

Related Questions

How you remove zero error from micrometer screw gauge?

To remove zero error from a micrometer screw gauge, first, close the micrometer completely and check the reading on the scale. If it does not read zero, note the error value. To correct for this error in future measurements, simply add or subtract the zero error value from your measurements, depending on whether it is a positive or negative error. Alternatively, you can adjust the micrometer's anvil or spindle if it has a calibration feature to bring it back to zero.


What is the 'zero error' in vernier calipers and micrometer screw gauge?

In vernier calipers, zero error is when the jaws of the caliper do not close properly when they are in contact without measuring anything, resulting in a measurement that is not accurate. In a micrometer screw gauge, zero error occurs when the flat end of the spindle does not perfectly align with the reference line on the sleeve at zero reading, leading to inaccurate measurements.


What instrument measures the volume of a screw?

A micrometer (or micrometer screw gauge) measures the volume of a screw.


What is the principle of micrometer?

The principle of a micrometer is based on the rotation of a screw to precisely measure small distances. The screw moves a spindle, which is connected to a scale that indicates the measurement. By calibrating the micrometer scale, accurate readings can be obtained.


What is zero error of micrometer?

.005mm


Why is screw gauge commonly called as micrometer screw gauge?

A micrometer screw gauge is commonly known as a micrometer. This is a form of calipers used for measuring small dimensions. Screw gauge in extensively used in the engineering field for obtaining precision measurements. The article describes the principle and main parts of a basic micrometer screw gauge.


How do you measure from micrometer of dia?

Put it between two jaw piece micrometer. Screw close movable jaw. And read on a micrometer ruler.


What are the calcification of the micrometer?

The build up of calcium deposits in a micrometer. It may happen as a result of dust from blackboard chalk settling in the screw mechanism of the micrometer.The build up of calcium deposits in a micrometer. It may happen as a result of dust from blackboard chalk settling in the screw mechanism of the micrometer.The build up of calcium deposits in a micrometer. It may happen as a result of dust from blackboard chalk settling in the screw mechanism of the micrometer.The build up of calcium deposits in a micrometer. It may happen as a result of dust from blackboard chalk settling in the screw mechanism of the micrometer.


What is the precautions you should take when using a micrometer screw gauge?

it should be clean and dry there should be no error the thimble shouldnt be too tight


How do you take readings from a micrometer screw gauge?

The first step is to find the zero error and hence the zero correction. Rotate the micrometer until the fixed and movable jaws contact each other - not too hard and not too soft but just right, you should geta feel for this. Rarely will a micrometer will read zero. You need to figure out the zero error. It may be positive or negative. If the zero error is positive then the zero correction is negative and vicevers. Now open the micrometer and insert the object to be measured and close the micrometer with ideally the same sense of pressure you felt when you found the zero error. Now read the micrometer. You add the zero correction to get the true value.


What is equal to the pitch of the precision ground spindle screw on a micrometer 0.01mm 0.10mm 0.05mm or 0.50mm?

The pitch of the precision ground spindle screw on a micrometer is typically 0.5mm.


How zero error removed from micrometer?

To remove zero error from a micrometer, first ensure that the micrometer is closed completely without any object between the measuring surfaces. Then, check the reading on the scale; if it does not read zero, note the error value. Adjust the micrometer’s zero setting, if it has one, or account for the error in future measurements by subtracting the zero error from your readings. Finally, recalibrate the device regularly to maintain accuracy.