funtion of the low pressure control is to pump down compressor in case of low pressure in the system

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

Which part of the centrifugal pump increases the pressure of the liquid?

volute and or diffuser


What is the proper definition of chillers?

The definition of the word, chillers, is a machine that removes the heat from a liquid and cools an object by doing so. An air conditioning unit can be called a chiller.


Is the vapor pressure of a liquid a linear function of temperature?

If the temperature of the liquid is raised, more molecules escape to the vapor until equilibrium is once again established. The vapor pressure of a liquid, therefore, increases with increasing temperature.


What is volute centrifual pump?

The volute of a centrifugal pump is the tank that holds the liquid being pumped. The centrifugal pump is a type of pump that uses a swirling motion to pump liquid.


Why do you start the centrifugal pump with the discharge valve shut?

centrifugal pump should be fill with liquid to built discharge pressur.chemist.yasser.Naguib


Why cavitation will occur in Centrifugal Pumps and not in displacement pumps?

Cavitation occurs when the pressure on a liquid drops below the vapor pressure for the liquid or when gas is otherwise introduced to a pump such that it disrupts the flow of the liquid through the pump.Positive displacement pumps trap a quantity of liquid (or gas) and then increase the pressure by pushing (displacing) it into the discharge pipe. External pressure pushes the liquid into the pump chamber which then is made smaller before the pump chamber discharges its contents. If any gas enters the pump chamber along with a liquid it is simply compressed along with the liquid. Positive displacement pumps work just fine with both gases and liquids - although when gases are being compressed it is usually necessary to cool the pump chamber which heats up quite a bit during the almost adiabatic compression step of the pump. Cavitation does not occur in part because the pressure in the pump chamber is almost completely uniform. If the compression chamber drops below the vapor pressure of a liquid being pushed into it, the external pressure will continue to push the liquid in, then when the pump begins to decrease the volume, the valve allowing the liquid to enter will close and the volume of the contents is decreased until the pressure rises back above the vapor pressure of the liquid and it condenses in the pump chamber.A centrifugal pump uses a rotating impeller to increase the pressure and flow rate of a fluid. In centrifugal pumps, pressure is added by increasing the kinetic energy of the liquid and then, in essence, "throwing" the liquid into the discharge pipe where the higher kinetic energy liquid pushes on the liquid ahead of it to increase pressure. As the impeller moves through the liquid being pumped, it pushes on the liquid ahead of it, imparting additional kinetic energy to it. The liquid behind the impeller, however, actually experiences a little bit of a drop in pressure as the impeller tries to move away from it. Because liquids are fairly incompressible, this usually does not create any problem and the internal pressure of the liquid is sufficient to keep it in contact with the backside of the impeller. If the drop in pressure is low enough that the pressure drops below the vapor pressure of the liquid at the temperature present in the pump, the liquid will begin to vaporize. Once gas is present in the pump, it begins to cavitate - the liquid separates from the back of the impeller - especially near the tips. For this reason, introducing air or other gas into the liquid can cause cavitation, even if the pressure never drops below the vapor pressure of the liquid being pumped. This is also why centrifugal pumps are usually "primed" prior to being started up - to get all, or at least most, of the gas out of the line so that the pump won't cavitate.


What happen when you increase the pressure of nitrogen beyond the critical pressure and will it still exist in liquid phase?

The state of an element is a function of both pressure and temperature.


What is the use of centrifugal pump in the ship?

to pump out liquid or gas in higher quantity


What is purpose balance line in centrifugal compressor?

The purpose of the balance line in a centrifugal compressor is to equalize the pressure between the high-pressure and low-pressure sides of the impeller. This helps to reduce axial thrust, which can lead to mechanical wear and inefficiency. By allowing a controlled flow of gas or liquid to bypass the impeller, the balance line aids in stabilizing rotor operation and improving overall performance. It is essential for maintaining the reliability and longevity of the compressor system.


How does straw function while drink?

When you 'suck' on a straw, you reduce the air pressure inside it. This means the air pressure on the surface of the liquid outside the straw is greater - so it pushes down, which forces liquid up the straw into your mouth.


What is the relationship ofbetween liquid pressure and depth of a liquid?

In general, the pressure increases more or less linearly as a function of depth. For example, in the case of water, the pressure increases by approximately 1 bar (which is also approximately 1 atmosphere) every 10 meters you go down.


What is the relationship between liquid pressure and the depth of a liquid between liquid pressure and density?

pressure of liquid on bottom=density*gravitational force*depth :)