Yes, it is permitted to bring both bare equipment grounding conductors from two nonmetallic-sheathed cables directly to the grounding terminal of a receptacle. However, ensure that the grounding conductors are properly connected and that the total number of conductors does not exceed the manufacturer's specified terminal capacity. Additionally, it's important to follow local codes and regulations to ensure compliance with safety standards.

User Avatar

AnswerBot

3mo ago

What else can I help you with?

Related Questions

What are the requirements for equipment grounding conductors as specified in NEC 300.4?

The requirements for equipment grounding conductors specified in NEC 300.4 include ensuring they are continuous, securely connected, and sized according to the current-carrying conductors.


What information is provided in the equipment grounding chart?

The equipment grounding chart provides information on the proper grounding requirements for electrical equipment to ensure safety and prevent electrical hazards. It includes details on the size and type of grounding conductors, grounding electrode systems, and bonding requirements for different types of equipment.


When you encounter a four-slot receptacle in a residential laundry room?

It allows for a separate equipment grounding conductor


Is it always necessary to attach the bare equipment grounding conductor of a nonmetallic-sheathed cableto the green hexagon-shaped grounding screw on a receptacle?

Yes, it is necessary to attach the bare equipment grounding conductor of a nonmetallic-sheathed cable to the green hexagon-shaped grounding screw on a receptacle. This connection ensures proper grounding, which is essential for safety by preventing electrical shock and reducing the risk of electrical fires. Proper grounding also helps protect equipment and improves the overall reliability of the electrical system.


Is a grounding 120 volt receptacle larger than an ordinary receptacle?

No, it just has an additional conductor to separate the neutral from the ground, and has a third prong in the receptacle to receive the appliance grounding conductor through the cordset.


What information can be found in the NEC grounding table?

The NEC grounding table provides information on the minimum size of grounding conductors based on the type and size of electrical equipment being used.


Is it always necessary to attach the bare equipment grounding conductor of a nonmetallic sheathed cable to the green hexagon shape grounding screw on a receptacle?

Yes, it is necessary to attach the bare equipment grounding conductor of a nonmetallic sheathed cable to the green hexagon-shaped grounding screw on a receptacle. This connection ensures that the grounding system is properly established, providing a safe path for fault currents and reducing the risk of electric shock. Proper grounding enhances the overall safety of the electrical system by preventing electrical hazards.


What are the benefits of using a self-grounding receptacle in electrical installations?

Using a self-grounding receptacle in electrical installations provides a safer and more reliable connection to the ground wire, reducing the risk of electrical shocks and fires. This type of receptacle ensures proper grounding without the need for additional grounding wires, simplifying installation and maintenance.


On a duplex grounding type receptacle what is strap or yoke?

The strap or yoke on a duplex grounding type receptacle is the metal component that connects the two outlets together. It serves as the common connection point for the ground wires in the receptacle to ensure proper grounding.


The minimum acceptable tension force of the grounding contact in a receptacle is?

The minimum acceptable tension force for a grounding contact in a receptacle is typically specified by the manufacturer and can vary depending on the specific design and application requirements. It is important to refer to the product specifications or industry standards to determine the appropriate tension force for the grounding contact.


What is the recommended equipment grounding conductor size for ensuring electrical safety in a commercial building?

The recommended equipment grounding conductor size for ensuring electrical safety in a commercial building is typically determined by the National Electrical Code (NEC) and is based on the size of the circuit conductors being used. It is important to follow the guidelines provided in the NEC to ensure proper grounding and safety in the building.


Is it safe to glue or tape an electrical socket in place?

No, the receptacle needs the screws in place to complete the bond between the metal component of the receptacle to the metal component in the receptacle's junction box. This bond is entirely separate from the grounding of the receptacle.