Used in power generation. When steam turbine is on-line the Main Steam Stop Valve is fully open. When offline it is closed. Steam to turbine is controlled thru control valves after Main Steam Stop Valve
The steam stop valve on a boiler is a safety device. In the event that the boiler overheats, the steam stop valve is opened to allow steam to escape to another tank in the boiler system that is away from the main tank.
The main stop valve in any steam turbine is the emergency trip valve. This valve is manually opened and will close automatically under emergency conditions.
This is usually coupled with a manual isolation valve so that repairs can be made on the main stop when needed. The throttle valve comes after the main stop and is used to admit steam to the steam chest in a controllable manner.
All the emergency trips on a turbine will activate the trip mechanism for the main stop individually, closing off steam to the turbine immediately.
For a steam engine, the steam(throttle) valve that sets the engine speed/power is often known as a regulator. k.Shiva
The Emergency Stop Valve (ESV) in a turbine is placed between the steam engine and the turbine structure. It is designed to rapidly close and prevent steam from reaching the turbine in case of emergency.
Steam turbine nozzle clearance is the total energy content available in steam. This is through a valve.
Which actually Actuates the Steam Control Valve
In large turbines, a valve controls steam flow to groups of nozzles. The number of open valves controls the number of nozzles in use according to the load. A bar-lift or cam arrangement operated by the governor opens and closes these valves in sequence. Such a device is a multi-port valve. Using nozzles at full steam pressure is more efficient than throttling the steam.
The function of steam stop valve to supply steam to steam maniform and the function safety valve to prevent the steam high pressure over.
It is a stop valve placed on an auxiliary piece of equipment. Or it could be placed at the steam main to feed an auxiliary steam system (heating, auxiliary pumping. etc.). It is not the Main steam stop for the boiler or the prime mover (engine, turbine, process), it is for a secondary service.
Essentially its the pressure prior to entering the turbine chamber via the MSV (main stop valve)
Stop Boiler Valve (or Crown Valve) is installed on an outlet line of a boiler. It's purpose is isolation of a boiler from a downstream steam line. Its position may be either open or close, it cannot be used for throttling of steam.
It's a valve that regulates the main water pipe.
You Can Find Out About And Download Steam By Valve Corporation By Going To: http://store.steampowered.com And Clicking The Icon That Says: "Get Steam Now" Or You Can Download It Directly From The Valve Download Mirror: (In Case The Link On The Main Page Doesn't Work) http://storefront.steampowered.com/download/SteamInstall.msi
The purpose of a steam trap is to stop steam from passing beyond its point of use. A steam trap performs two functions. One is that it is an air vent. Two, is that it is a water outlet valve.
The valve seat or washer on the main valve are not seating/sealing properly.
The "curb stop" is the valve that is on the service from the main into your house. i.e. The 8" main in the street has a saddle tap with your 3/4" service line on it. Within 8 ft of the connection between your service and the main is your curb stop. The curb stop is a valve buried underground. In order to open/close the valve a curb box is placed over the valve. It is essentially a metal tube that lets you open and close the curb stop.
For a steam engine, the steam(throttle) valve that sets the engine speed/power is often known as a regulator. k.Shiva
There are two steam challenges in the third rescue. 1) The radiator : beginning from the first open pipe, turn each swivel valve to direct the steam through closed pipes until it reaches the expansion joint at the upper left, which explodes. Enter the Boiler Room. 2) The Engineer: climb the center section to the upper right, and avoid the steam there. the engineer will show you how to stop the steam: she turns the Green valve, which is connected to another valve at the far left. Go there and turn that valve. Repeat the process for the other three pairs of valves: Blue : middle right and then lower left Orange : bottom right and then middle left Red : bottom left and then middle left
Steam turbine nozzle clearance is the total energy content available in steam. This is through a valve.