16 gauge pipe refers to the wall thickness of the pipe exclusive of its diameter.It is 0.064 inches thick, this is a steel wire gauge measurement.Pipes are typically sold by schedule numbers. A wall thickness of 0.064 inches would correspond to pipe schedule 40 for 1/8" diameter pipe (0.068"), schedule 10 for 1/4" and 3/8" pipe (0.065") and schedule 5 for pipe diameters 1/2" to 2" (0.065"). Over 2" diameter pipe, schedule 5 (the smallest wall thickness) is thicker than 16 gauge steel.
Pipe schedule tell you something about the wall thickness of a pipe. Higher schedule means thicker wall. The actual thickness must be read from a pipe specification sheet, as it differs from material to material. Typical pipe sch. are Sch 20, 40, 80, 160, XS, XXS.
It depends on whether the pipe is open or closed and what it contains. If the pipe is full of water to a height of 40 m and open at the top, the pressure at the bottom is about 57 psig. The diameter doesn't matter.
500 kilos
40 stands for carbon percentage and 8 indicates the designation of carbon
The schedule value refers to the thickness of the wall of the pipe; the bigger the number (schedule) the bigger the wall thickness is of the pipe. The thickness is relative to the diameter of the tube/pipe an the application it is being used in.
It depends on the nominal diameter of pipe, but in actual sch-40 thickness is lesser than sch-80.
6
16 gauge pipe refers to the wall thickness of the pipe exclusive of its diameter.It is 0.064 inches thick, this is a steel wire gauge measurement.Pipes are typically sold by schedule numbers. A wall thickness of 0.064 inches would correspond to pipe schedule 40 for 1/8" diameter pipe (0.068"), schedule 10 for 1/4" and 3/8" pipe (0.065") and schedule 5 for pipe diameters 1/2" to 2" (0.065"). Over 2" diameter pipe, schedule 5 (the smallest wall thickness) is thicker than 16 gauge steel.
The inside diameter = 40 - 2 x 1.6 = 40 - 3.2 = 36.8 mm
The wall thickness of 4" Sch 40 pipe is 0.237 inches.The outer diameter is 4.5 inches and the inner diameter is 4.026 inches.
the wall thickness of sch 40 - 500mm dia pipe is 15mm or 16mm.
What does the schedule have to do with the material as schedule is the wall thickness Schedule 10, 20, 40 80 and 120 (XXH) The Schedule is telling you the wall (INTERNAL) thickness 10, 20 40, 80 and 120 XXH Whether it be steel, brass, galvanized and wrought ` About the pressure capacity, it is not the same because every material such as steel, brass, galvanized or wrought has a different strenght of materials.
it is, probably, a pipe with nominal diameter (DN) 6 mm, and wall thickness 1.727 mm (SCHEDULE 40). See it here: http://en.wikipedia.org/wiki/Nominal_Pipe_Size
the wall thickness of sch 40 - 500mm dia pipe is 15mm or 16mm.
Weight of pipe per Meter in Kg for MS Pipes = 3.14 * (Outer diameter of pipe in Mtr. - wall thickness in Mtr. ) * Wall Thickness in Mtr. * 7850
The gauge of the pipe is the wall thickness. It is easier to say Schedule 40 pipe than .180 inch wall thickness. This is the SCH 40 wall thickness for a standard 12" pipe and the actual gauge thickness will vary based on pipe size and material. The larger the Schedule number, the thicker the pipe wall thickness. Pipe Schedule is also expressed in Std., X-Stg., and XX-Stg. since some thicknesses are more common than others.