answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: What is meaning of lv leads hv with 30 degree?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the meaning of 32Yd1 on a transformer?

This is 3 Nos Two Winding Transformers put together to form of Three Phase transformer, HV is Star Connected & LV is Delta Connected in the LV phase is leading by 30 Degree with respect to HV phase


What is the meaning of DYN 11 on a transformer nameplate?

What does Dd0, Dyn11, YNd5 etc. mean?First symbol/symbols, capital letters: HV winding connection.Second symbol/symbols, small letters: LV winding connection.Third symbol, number: Phase displacement expressed as the clock hour number.Winding connection designationsHigh Voltage Always capital lettersDelta - DStar - SInterconnected star - ZNeutral brought out - NLow voltage Always small lettersDelta - dStar - sInterconnected star - zNeutral brought out - nPhase displacementPhase rotation is always anti-clockwise. (international adopted convention)Use the hour indicator as the indicating phase displacement angle. Because there are 12 hours on a clock, and a circle consists out of 360°, each hour represents 30°.Thus 1 = 30°, 2 = 60°, 3 = 90°, 6 = 180° and 12 = 0° or 360°.The minute hand is set on 12 o'clock and replaces the line to neutral voltage (sometimes imaginary) of the HV winding. This position is always the reference point.Because rotation is anti-clockwise, 1 = 30° lagging (LV lags HV with 30°)and 11 = 330° lagging or 30° leading (LV leads HV with 30°)To summarise:Dd0Delta connected HV winding, delta connected LV winding, no phase shift between HV and LV.Dyn11Delta connected HV winding, star connected LV winding with neutral brought out, LV is leading HV with 30°YNd5Star connected HV winding with neutral brought out, delta connected LV winding, LV lags HV with 150°


What is the difference between Dyn-11 and Ynd-11?

Winding connection designations High Voltage Always capital letters Delta - D Star - S Interconnected star - Z Neutral brought out - N Low voltage Always small letters Delta - d Star - s Interconnected star - z Neutral brought out - n Phase displacement Phase rotation is always anti-clockwise. (international adopted convention) Use the hour indicator as the indicating phase displacement angle. Because there are 12 hours on a clock, and a circle consists out of 360°, each hour represents 30°. Thus 1 = 30°, 2 = 60°, 3 = 90°, 6 = 180° and 12 = 0° or 360°. The minute hand is set on 12 o'clock and replaces the line to neutral voltage (sometimes imaginary) of the HV winding. This position is always the reference point. Because rotation is anti-clockwise, 1 = 30° lagging (LV lags HV with 30°)and 11 = 330° lagging or 30° leading (LV leads HV with 30°) To summarise: Dd0 Delta connected HV winding, delta connected LV winding, no phase shift between HV and LV. Dyn11 Delta connected HV winding, star connected LV winding with neutral brought out, LV is leading HV with 30° YNd5 Star connected HV winding with neutral brought out, delta connected LV winding, LV lags HV with 150° " So there is no specification of Dy11.. it will be Dyn11 "


How do you repair the HV winding of casting resin power transformer dry type 1600 kVA 66042 kV insulation class 155 C degree?

what do you mean repair hv winding whats wrong with it


What is the full form of hv?

What is fullform of hv


The fastest 22 magnum bullet made?

2250 fps - 22 Winchester Mag. 30 gr. Varmint HV


Th?

Hv 


When was Josh Kloss born?

He is now 30 years old , I couldn't know when he was born exactly but , now he is 30 years old , born in 1981 , in portland ..... hv a nice day :-) Ryan


Is the Elmo HV-5100XG Overhead Projector hard to use?

The Elmo HV series are simple to use, but calibrating can be difficult.


What meters are kept on HV side in SC test?

insulation tester (Megger) can used to checked the short circuit on HV side. HI POT tester is also a means to checked the shot circuit in HV cable.


Will the Elmo HV-5100XG Overhead Projector be good for a presentation?

The Elmo HV series are great for presentations and have very strong colors.


What is the meaning of suffix YNaOd1 in vector group of transformer?

i understand that YNaOd1 represent an auto transformer with HV winding as wye connected and loaded tertiary. Please correct me if i am wrong.