Chillers using CFC-11 require purge units to remove non-condensable gases that can accumulate within the refrigeration system. These gases can reduce efficiency and lead to operational issues by disrupting the heat exchange process. The purge unit ensures that these gases, which can include air or other contaminants, are expelled from the system, maintaining optimal performance and preventing damage to the chiller. Additionally, purging helps to minimize the potential for leaks and environmental harm associated with CFC-11.

User Avatar

AnswerBot

2mo ago

What else can I help you with?

Continue Learning about Movies & Television

Purge units on centrifugal chillers removes?

Purge units on centrifugal chillers are designed to remove non-condensable gases, such as air and moisture, from the refrigerant system. These gases can compromise the efficiency of the chiller by reducing heat transfer and increasing energy consumption. By continuously monitoring and venting these gases, purge units help maintain optimal performance and prolong the life of the chiller. This process ensures that the refrigerant remains as pure as possible, enhancing overall system reliability.


What is meant by the high efficiency purge unit?

A high efficiency purge unit is a system designed to effectively remove contaminants or unwanted substances from a gas or liquid stream, often used in industrial processes. These units typically utilize advanced filtration and separation techniques to achieve a high level of purity, ensuring that the output meets stringent quality standards. They are commonly employed in applications such as semiconductor manufacturing, chemical processing, and environmental control, where maintaining clean conditions is critical for optimal performance and safety.


Relation between units of lengths mass and capacity?

There is no relationship between units of mass and either length of capacity. Units of capacity are the cubed units of length.


What is the no of execution units present in Pentium microprocessor?

2 execution units


Why is it necessary to have fractional units?

Not all magnitudes in nature come in integer units.

Related Questions

Do all AC units have freon?

no, water is used in case of chillers...


Why do chillers using CFC-11 and HCFC-123 require purge units?

These refrigerants have higher boiling points than say R12 or R22. Thus when a machine using them operates the low side will run in a vacuum. So any low side leak points will suck in air rather than leak refrigerant out. A purge unit constantly samples the condenser gas and removes the air and water vapor which has been pulled in at these leaking points and periodically releases them to atmosphere while it condenses any refrigerant vapor picked up in the sample mix to a liquid and returns it to the machine.


Do window AC units require freon for operation?

Yes, window AC units require refrigerant, such as Freon, for operation. Refrigerant is essential for the cooling process in the air conditioner.


What conversion factor do complex conversions between units require?

SMID


What are some portable AC units that do not require a hose for ventilation?

Some portable AC units that do not require a hose for ventilation are the Evapolar Personal Air Cooler, the Zero Breeze Mark 2, and the Coolala Portable AC.


Do window units need Freon for proper functioning?

Yes, window air conditioning units require refrigerant, such as Freon, to properly cool the air.


Does air conditioning units for manufactured homes use water?

Some heat pumps use shallow wells to draw water, transfer heat, and return the water to a second shallow well. All other A/C units using water are called chillers or cooling towers, and even a small unit is larger than a semi truck trailer..


How many car tires are in a ton?

This answer really depends upon the size of the unit in question. Smaller units will require more in number in comparison with larger units.


How do i install an engine block heater in a 2001 Hyundai Elantra?

There are some units that replace the oil dipstick There are some units that require removing a freeplug and replacing with blockheater


When you are solving for mechanical advantage what units did the final answer require?

None. Mechanical advantage is a ratio of two measures each of which has the same units and so it is a unit-less number.


Why are square units used when working with a three dimensional figure?

Because the surface areas of 3-d figures are two-dimensional and their measures require square units.Because the surface areas of 3-d figures are two-dimensional and their measures require square units.Because the surface areas of 3-d figures are two-dimensional and their measures require square units.Because the surface areas of 3-d figures are two-dimensional and their measures require square units.


Dose slendertone flex max require a controler?

No, Slendertone Flex Max does not require a handheld controller. The unit which is attached to the front of the belt is powered by batteries and operates the belt. The newer models operate via a handheld controller and these are compatible with a number of products which target different areas of your body. The handheld units are rechargeable units that do not require batteries.