Yes, as long as the lug connects to the panel thye same way.
GE circuit breakers with catalog numbers ranging from THQL1115 through to THQL1150 can be substituted like for like with Cutler-Hammer circuit breakers coded CL115 through to CL150, ITE Siemens circuit breakers coded Q115 through to Q150 and Square D circuit breakers coded HOM115 through to HOM150. These are single pole breakers. GE circuit breakers with catalog codes from THQL2115 through to THQL2150 can be substituted with Cutler-Hammer circuit breakers CL215 through to CL250, Square D circuit breakers HOM215 through to HOM250 and ITE Siemens circuit breakers Q215 through to Q250 of the same amperage and voltage. These are double pole breakers.
GE circuit breakers with catalog numbers ranging from THQL1115 through to THQL1150 can be substituted like for like with Cutler-Hammer circuit breakers coded CL115 through to CL150, ITE Siemens circuit breakers coded Q115 through to Q150 and Square D circuit breakers coded HOM115 through to HOM150. These are single pole breakers. GE circuit breakers with catalog codes from THQL2115 through to THQL2150 can be substituted with Cutler-Hammer circuit breakers CL215 through to CL250, Square D circuit breakers HOM215 through to HOM250 and ITE Siemens circuit breakers Q215 through to Q250 of the same amperage and voltage. These are double pole breakers.
Siemens and Eaton are two common brands that make breakers that are compatible with Gould GFCI breakers. Ensure to check the specifications and compatibility to make sure the replacement breaker will work properly in your electrical panel.
In my experience, NOTHING is compatible with a Murray panel. Others claim there are certain Siemens and Federal Pacific breakers or Eaton type "CL", but you might have to obtain permission from the inspector to use anything other than Murray.
Siemen's is a brand of electrical breakers that will cross reference with GE thqb series breakers. Electrical breakers can be replaced by other brands if they are of the same type and fit in an electrical box.
GE circuit breakers with catalog numbers ranging from THQL1115 through to THQL1150 can be substituted like for like with Cutler-Hammer circuit breakers coded CL115 through to CL150, ITE Siemens circuit breakers coded Q115 through to Q150 and Square D circuit breakers coded HOM115 through to HOM150. These are single pole breakers. GE circuit breakers with catalog codes from THQL2115 through to THQL2150 can be substituted with Cutler-Hammer circuit breakers CL215 through to CL250, Square D circuit breakers HOM215 through to HOM250 and ITE Siemens circuit breakers Q215 through to Q250 of the same amperage and voltage. These are double pole breakers.
In my experience, NOTHING is compatible with a Murray panel. Others claim there are certain Siemens and Federal Pacific breakers or Eaton type "CL", but you might have to obtain permission from the inspector to use anything other than Murray.
GE circuit breakers with catalog numbers ranging from THQL1115 through to THQL1150 can be substituted like for like with Cutler-Hammer circuit breakers coded CL115 through to CL150, ITE Siemens circuit breakers coded Q115 through to Q150 and Square D circuit breakers coded HOM115 through to HOM150. These are single pole breakers. GE circuit breakers with catalog codes from THQL2115 through to THQL2150 can be substituted with Cutler-Hammer circuit breakers CL215 through to CL250, Square D circuit breakers HOM215 through to HOM250 and ITE Siemens circuit breakers Q215 through to Q250 of the same amperage and voltage. These are double pole breakers.
Siemens and Eaton are two common brands that make breakers that are compatible with Gould GFCI breakers. Ensure to check the specifications and compatibility to make sure the replacement breaker will work properly in your electrical panel.
In my experience, NOTHING is compatible with a Murray panel. Others claim there are certain Siemens and Federal Pacific breakers or Eaton type "CL", but you might have to obtain permission from the inspector to use anything other than Murray.
Siemen's is a brand of electrical breakers that will cross reference with GE thqb series breakers. Electrical breakers can be replaced by other brands if they are of the same type and fit in an electrical box.
ITE EQB circuit breakers can typically interchange with Siemens EQB breakers, as Siemens acquired the ITE brand. Additionally, some GE circuit breakers may be compatible, depending on the specific model and application. However, it's crucial to verify compatibility based on the electrical system and local codes, as interchanging breakers can pose safety risks if not done correctly. Always consult with a qualified electrician before making any changes.
Breakers are build to snap onto a buss bar in a breaker panel. If they look the same on the back end then they will likely work. If not do not try to force a fit. To add a little more to this: 1st of all it depends on what kind of Square D you are talking about. Square D Homline breakers will fit in a GE panel but GE breakers will not fit into a Homeline panel in my experience. Square D QO is not compatible with either.
No, only Sq D breakers will fit into a Sq D panel. I believe Square D makes at least two styles of breakers. Home and industrial. I have a GE entrance/distribution box that has Square D (home), Murray, Bryant, Westinghouse, and GE breakers, all working together. I hope this helps.
Cooper breakers
The GE breaker compatibility chart provides information on which types and models of circuit breakers are compatible with specific GE electrical panels. This chart helps users determine which breakers can be safely installed in their electrical system to ensure proper functioning and safety.
Possibly. Depends on which model Siemens breaker you have.