Yes, but the code states that the white wire has to be identified as a current carrying conductor. This is done by wrapping some black or red electrical tape around the white wire. This lets anyone else that works on the system know that it is not a neutral, but a "hot" wire.


<><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Natural Sciences

What wire gauge and amperage for a 1600 watt wall heater?

1600 watts is unusually low for electric baseboard heaters! These usually are rated at about 6000 watts.Typical electric baseboard heaters operate on 220 volts thus you heater would pull about 7.3 amperes and 16 gauge wire can easily handle this.A standard 6000 watt baseboard heater pulls about 27 amperes and needs 10 gauge wire.


How many 240 volt electric baseboard heaters can you connect to a number 10 wire?

You can connect up to three 240 volt electric baseboard heaters to a number 10 wire circuit. It is important to follow the local electrical code and manufacturer's guidelines to ensure the safe and proper installation of the heaters. Consulting with a licensed electrician is recommended for any electrical work.


Can you use 12-2 and a double 20 amp breaker to run a basebord heater rated at 4.2 amps and the thermostat rated at 17 amps?

Answer for USA, Canada and countries running a 60 Hertz supply service.The thing to consider here is the current rating of the baseboard heater. If the baseboard heater is 240 volt then yes you would need to use a two pole breaker. If you are using just one heater on the circuit, the current rating of the heater is low enough that you could use a two pole breaker rated at 15 amps and copper wire rated at #14 . The rating of the thermostat is the maximum that the stat will handle safely. With the combination you suggest you could run a total of 3800 watts of baseboard heaters. In amps this would be 16 and well within the rating of the stat.


What size breaker and wire for 2000 watt heater?

A 2000 watt heater draws 8.3 amps on a 240 v supply, so the cutout should be set to 10 or 12 amps. &lt;&lt;&gt;&gt; In North America a 2000 watt baseboard heater will be fed with a two pole 15 amp breaker. A two wire cable of #14 copper will be used to connect the supply voltage to the heater.


How do you connect a 240 volt electric heater It is a baseboard unit the has a black and red internal wire for connection Do you use 12 2 wire or 12 3 wire The thermostat has 2 red 2 black wire?

2 wire (plus ground) is all you need for a 240 volt heater provided there is no 120 volt accessories in the heater such as a built in convenience receptacle. If cable is used, the white wire of the 2 wire cable will be a HOT-LEG even though it is white-this is one of the code exceptions. The size of the guage is dependent on the size of the load and other factors. 12 guage will handle up to 1500 watts generally.

Related Questions

How do you wire in a lowvoltage thermostat control to a baseboard heater?

Most baseboard heaters use hi voltage thermostats.


How to wire a baseboard heater properly?

To wire a baseboard heater properly, first turn off the power to the circuit. Connect the heater's wires to the corresponding wires in the electrical box using wire connectors. Make sure to follow the manufacturer's instructions and local electrical codes. Finally, secure all connections and turn the power back on to test the heater.


How do I properly wire a baseboard heater for optimal performance and safety?

To properly wire a baseboard heater for optimal performance and safety, follow these steps: Turn off the power to the circuit where the heater will be installed. Use the correct gauge wire for the heater's voltage and amperage requirements. Connect the wires to the heater according to the manufacturer's instructions. Use wire connectors to secure the connections and prevent them from coming loose. Install a dedicated circuit breaker for the heater to prevent overloading the circuit. Test the heater to ensure it is working properly before use. By following these steps, you can ensure that your baseboard heater is wired correctly for optimal performance and safety.


What wire gauge and amperage for a 1600 watt wall heater?

1600 watts is unusually low for electric baseboard heaters! These usually are rated at about 6000 watts.Typical electric baseboard heaters operate on 220 volts thus you heater would pull about 7.3 amperes and 16 gauge wire can easily handle this.A standard 6000 watt baseboard heater pulls about 27 amperes and needs 10 gauge wire.


How do you wire a baseboard heater?

To wire a baseboard heater, you need to connect it to a dedicated circuit breaker in your electrical panel using the appropriate gauge wire. Make sure to follow the manufacturer's instructions and local electrical codes for proper installation. It is recommended to hire a licensed electrician for this task to ensure safety and compliance.


Where does the red wire in a baseboard heater connect to the black or white wire in the wall?

In the heater you will have two wires. You should then have 2 supply wires from the panel, and 2 wires from the thermostat. The neutral (white) supply wire should go to one of the wires on the heater. The hot (black) supply wire should connect to one wire from the thermostat. The other wire from the thermostat will connect to the other wire from the heater.


How do you wire an electric baseboard heater?

To wire an electric baseboard heater, you need to connect it to a dedicated circuit breaker in your electrical panel using the appropriate gauge wire. Make sure to follow the manufacturer's instructions and local electrical codes for proper installation. It is recommended to hire a licensed electrician for this task to ensure safety and compliance.


What is the most reliable source for an electric baseboard heater wiring diagram?

The most reliable source for an electric baseboard heater wiring diagram is the manufacturer's official website or the user manual that came with the heater. These sources provide accurate and detailed information on how to properly wire the heater for safe and efficient operation.


What size wire do you use if you are require to wire a 6-20amp 220volt outlet?

# 6 wire


How many 240 volt electric baseboard heaters can you connect to a number 10 wire?

You can connect up to three 240 volt electric baseboard heaters to a number 10 wire circuit. It is important to follow the local electrical code and manufacturer's guidelines to ensure the safe and proper installation of the heaters. Consulting with a licensed electrician is recommended for any electrical work.


How do I properly wire a baseboard heater thermostat for optimal performance and safety?

To properly wire a baseboard heater thermostat for optimal performance and safety, follow these steps: Turn off the power to the heater at the circuit breaker. Connect the thermostat to the heater using the manufacturer's instructions. Use the correct gauge wire for the heater's voltage and amperage. Ensure all connections are secure and insulated. Turn the power back on and test the thermostat to ensure it is functioning correctly. It is recommended to consult a professional electrician if you are unsure about any step in the process.


What is the correct baseboard heater wiring diagram for installation?

The correct baseboard heater wiring diagram for installation involves connecting the heater to a dedicated circuit with the appropriate voltage and amperage, using the correct gauge of wire, and following the manufacturer's instructions for proper installation. It is important to ensure that the wiring is done safely and in compliance with local electrical codes.