Hire an electrician. While unintentional, the clearest statement of your question is that you don't know what you are doing. You want your over-current protection device to be the weakest link in your system, so it pops before anything is damaged. You're talking about hooking a 50A line up to a 100A breaker, making the wiring the weakest link. That is a good recipie for a house fire.

User Avatar

Wiki User

19y ago

What else can I help you with?

Continue Learning about Natural Sciences

Can an electric range be powered from the same circuit as an electric dyer?

No. The two appliances usually have dedicated circuits. The range will have a two pole 40 amp breaker and be fed with a 3-C #8 copper cable. The dryer will have a 30 amp two pole breaker and be fed with a 3-C # 10 copper cable. As you can see by powering a 40 amp device from a 30 amp breaker, full operation of the range will trip the 30 amp breaker.


Can you plug an electric range into an outlet on a 30 amp breaker?

Most Electric Ranges are plugged into a 50 A breaker for good reason. When everything is turned on it will likely draw more than 30 A. The first step is to find the rating plate on your range and see the current rating. If great than 24 A you shouldn't use 30 A breaker. Make sure connection wire is sized for the correct amperage.


Can you hook up a 240V circuit in series to a dryer and electric range?

The short answer is no. First off I assume you mean "can you have a dryer and an electric range on the same circuit?" (If they were actually wired in series, then you couldn't use your range if the dryer was off) In theory you could have them on the same circuit you just need to make sure that the wiring and the circuit they are on can handle the number of amps the two of them could draw together. If your breaker isn't big enough, it kill the power to the range while you are cooking dinner. If the wiring can't handle the load, then there is a fire risk. A dryer is usually on a 30amp circuit and a range is usually on a 50amp circuit, so to have them together would require an 80amp circuit, which will be difficult to find a breaker and wiring for.


How many amps does an electric range use?

Answer for USA, Canada and countries running a 60 Hertz supply service.A normal range in the home is wired with a 40 amp capacity wire #8, connected to a two pole 40 amp breaker.


Do you have to have a downdraft electric range with a down draft?

No, a downdraft electric range does not require a downdraft vent system to function properly. While they are often paired together for efficient ventilation, you can install a downdraft electric range without a downdraft vent by using an alternate ventilation method such as overhead hoods or external venting systems.

Related Questions

What size breaker should be used for an electric range?

A 40-50 amp breaker is typically used for an electric range.


What is the function of the breaker for an electric range?

The function of the breaker for an electric range is to protect the appliance and the electrical circuit from overloading or short circuits by interrupting the flow of electricity when there is a problem.


Can an electric range be powered from the same circuit as an electric dyer?

No. The two appliances usually have dedicated circuits. The range will have a two pole 40 amp breaker and be fed with a 3-C #8 copper cable. The dryer will have a 30 amp two pole breaker and be fed with a 3-C # 10 copper cable. As you can see by powering a 40 amp device from a 30 amp breaker, full operation of the range will trip the 30 amp breaker.


What is the purpose of a circuit breaker for an electric range and how does it function to protect the appliance from electrical overloads?

The purpose of a circuit breaker for an electric range is to protect the appliance from electrical overloads. It functions by automatically shutting off the power supply to the range when it detects a surge in electrical current, preventing damage to the appliance and reducing the risk of fire.


What are the electrical requirements for a 30 amp electric range?

A 30 amp electric range typically requires a dedicated 240-volt circuit with a 30 amp breaker and 10-gauge wiring.


Why are electric ranges wired to separate circuit breaker?

As a range is a high current device, the electrical code stipulates that it has to have its own breaker. The breaker protects the wire feeder. An electric range breaker is set to trip at 40 amps. Using a smaller wire that #8 is not allowed as their ratings are below that of the #8 wire. #10 wire rating is 30 amps, #12 wire rating is 20 amps, and #14 wire rating is 15 amps.


How difficult is it to install an island range?

It is fairly difficult. You will need to cut out a portion of the island for the range and have the proper electric and gas lines installed.


How do you know if you have a electric stove?

Go to your electric panel and see if you can find a 40 amp breaker. If you see one that there is a good chance that you have a electric stove in the kitchen. If you don't pay a gas bill then chances you are using an electrical range.


Electric range wiring specifications?

The most common size wire for an electric range is 3C - #8 connected to a 40 amp two pole breaker for operation on 240 volts. <<>> Wiring specifications are located on the unit nameplate, where the serial and model number are.


Can you plug an electric range into an outlet on a 30 amp breaker?

Most Electric Ranges are plugged into a 50 A breaker for good reason. When everything is turned on it will likely draw more than 30 A. The first step is to find the rating plate on your range and see the current rating. If great than 24 A you shouldn't use 30 A breaker. Make sure connection wire is sized for the correct amperage.


What is the recommended range breaker size for a circuit breaker in a residential electrical panel?

The recommended range breaker size for a circuit breaker in a residential electrical panel is typically between 15 to 20 amps.


What could be the reason why my electric range is not working properly?

There could be several reasons why your electric range is not working properly, such as a faulty heating element, a broken control panel, a tripped circuit breaker, or a problem with the power supply. It is recommended to check these components and consult a professional if needed.