answersLogoWhite

0

Flaming the culture tube after removing the cotton plug and before inserting it helps to create a sterile environment by killing any potential contaminants on the lip of the tube. This reduces the risk of introducing unwanted microorganisms into the culture medium.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Continue Learning about Natural Sciences

How can prevent splattering when flaming a loop which has just used to transfer a culture?

you should drawn the loop slowly from the cooler to the hotter part of flame.Heat from the base of the wire first and slowly move towards the loop's tip. Heat the wire until it is red-hot.


How do you prevent splattering when flamming a loop which has just been used to transfer a culture?

To prevent splattering when flaming a loop that has just been used to transfer a culture, make sure to let the loop cool slightly before placing it into the flame. Hold the loop at a slight angle while heating it to allow any excess liquid to drip off. Additionally, ensure that the loop is held steady and motionless in the flame to minimize any potential splattering.


Importance of flaming the edges of the petri plates before and after pouring the media?

Flaming the edges of the petri plates before pouring the media helps to create a sterile environment by killing any microorganisms present on the surface. Flaming the edges after pouring the media helps to prevent contamination of the agar surface by airborne microorganisms during incubation.


Why it is necessary to flame red-hot every time the culture is streaked on the petri dish?

Flaming the inoculating loop red-hot before streaking on a petri dish is essential for sterilization. This process eliminates any residual microbes, preventing contamination of the culture. Ensuring a sterile tool helps maintain the integrity of the experiment and allows for accurate observation of the cultured organism's characteristics without interference from unwanted microorganisms. Additionally, it promotes reliable results by minimizing variables that could affect the growth of the intended culture.


What is The piece of plastic that is used to make wells in an agarose gel called?

The piece of plastic used to create wells in an agarose gel is called a comb. It is inserted into the gel before it solidifies, creating indentations that serve as wells for loading samples during gel electrophoresis. Once the gel is set, the comb is removed, leaving behind the wells for sample application.

Related Questions

What is the importance flaming the mouth or lid of culture receptacles after opening and before closing them?

It help you eat and swallow. It pretty much keeps you alive


Why is flaming the neck of the tubes immediately after uncapping and before recapping is essential during subculturing?

Flaming sterilises the tube.


How can prevent splattering when flaming a loop which has just used to transfer a culture?

you should drawn the loop slowly from the cooler to the hotter part of flame.Heat from the base of the wire first and slowly move towards the loop's tip. Heat the wire until it is red-hot.


What is the purpose of flaming the loop before and after use?

Inoculating loop is used to inoculate microbial colony or sample on culture medium and to avoid the undesired microbial cells or to avoid contamination flaming of inoculating loop is necessary it is also called as incerination.


What is the reason for flaming the tubes before and after each transfer?

Flaming the tubes before and after each transfer is a crucial practice in microbiological techniques to prevent contamination. The heat creates a sterile environment by killing any potential microbes on the lip of the tube, ensuring that only the intended microorganisms are transferred. This helps maintain the integrity of the culture and ensures accurate experimental results. Additionally, it serves as a visual signal that the tube has been properly sterilized.


How do you prevent splattering when flamming a loop which has just been used to transfer a culture?

To prevent splattering when flaming a loop that has just been used to transfer a culture, make sure to let the loop cool slightly before placing it into the flame. Hold the loop at a slight angle while heating it to allow any excess liquid to drip off. Additionally, ensure that the loop is held steady and motionless in the flame to minimize any potential splattering.


What shape is a champagne cork BEFORE it's inserted into the bottle?

the tapered part of a champagne cork before it is inserted into a bottle is like a wine cork cylindrical and uniform


Once the morphine pump is incerted how much time left before death?

Once a morphine pump in inserted, there really is no way to tell how much time is left before death. This will vary greatly depending on the type of disease, the person's pain tolerance, and the medications used along with the morphine. Some people have a morphine pump inserted, get better, and have the pump removed.


How is a nasopharyngeal culture done?

The patient should cough before collection of the specimen. Then, as the patient tilts his or her head backwards, the caregiver will inspect the back of the throat using a penlight and tongue depressor. A swab on a flexible wire is inserted into.


Can I take misoprostol while I have an IUD inserted?

If you have an intrauterine contraceptive device in the uterus (e.g. the coil or the progesterone IUD), you must get it removed before your medical abortion. If you want to know more about misoprostol pill used for abortion, visit howtouseabortionpill.org.


Why is a nasogastric tube inserted before a colostomy?

A nasogastric tube is inserted from the nose to the stomach on the day of surgery or during surgery to remove gastric secretions and prevent nausea and vomiting.


Why are blogs being removed from the internet?

They are not being removed! There are more now then ever before.