Is the 220V plug 220V only or 110/220V? (The former will have 3 prongs and the former will have 4) If your case is the latter just use the ground, neutral, and one of the hots. This will give you 120V single phase. If the case is the former you can't get 110V off that plug.
You can, but your circuit will be "protected" by a 30 amp breaker. So you'll have to consider the safety issues of having wiring and appliances that can draw up to 30 amps before tripping the breaker. Will the wiring and circuity support that much current without damage? If not, then switch to a 15 or 20 amp breaker.
You can't "convert" a 120V receptacle into a 240V receptacle.A proper new 240V branch circuit complete with correctly sized circuit breakers, wiring and socket outlet is required.For more information see the Related Question shown below.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.
Yes, a 130 watt fan can be plugged into a 120 volt receptacle. The current draw will be I = W/E, Amps = Watts/Volts = 130/120 = 1.08 amps.
Reading 230V between neutral and hot on a dryer receptacle indicates a problem with the wiring setup. In a properly functioning system, you should read 240V between hot wires and 120V between hot and neutral. The issue could be due to a faulty connection, break in the wiring, or incorrect wiring at the receptacle. It's crucial to address this issue promptly to avoid potential safety hazards and damage to the appliance.
The article designations may change with the code cycle year. In the 2005 NEC see table 310-16 (allowable ampacities for conductors), also article 240.4(D) (protection of small conductors), also table 210.24 (summary of branch circuit requirements for muti-outlet branch circuits)
Don't!
You can't. I'm not sure exactly what you're trying to do, but the way it is written is not possible. It seems you might want to use half of a duplex receptacle for 120 and half for 240. This would not be code compliant, nor would it make sense. A plug designed for 240v will not even fit into a 120v receptacle. You need a 240 volt receptacle rated for the amperage you will need. Also, an existing 120v receptacle has nothing to do with your 240v receptacle. For a 240 volt receptacle, you'll need to run 2 new 120v lines (in the same cable). The existing 120v circuit cannot be used here, even if you added another 120v circuit, because when a load uses 240v, both 120v circuits supplying the 240v must be controlled by a common disconnect (a 2 pole breaker designed for 240v circuit). My advice would be to show an electrician what you want done. I'm sure they can tell you how to make that happen.
No. A household receptacle is 120V. It will not work.
You can, but your circuit will be "protected" by a 30 amp breaker. So you'll have to consider the safety issues of having wiring and appliances that can draw up to 30 amps before tripping the breaker. Will the wiring and circuity support that much current without damage? If not, then switch to a 15 or 20 amp breaker.
If the 2 hot wires are connected to either side of a receptacle, you have a 240v receptacle (assuming it's in the US). This is typically done for window air conditioners. But code requires that the receptacle have a different configuration than other receptacles in the building so you don't run the risk of plugging in a 120v device into a 240v receptacle.
It's the same receptacle, except L6 is 240V rated vs 120V rated for L5 (note: The answer above is incorrect. It is true that the L6-30 is a 240V rated connector, and the L5-30 is 125V rated. However they do not share the same pins, they are similar, but one connector will not mate with the other receptacle.)
Change the receptacle and the plug is the best way to do this. Provided you use a properly rated plug, changing the plug type will not affect the appliance at all.
Any electrical meter which measures volts or a standard plug tester. (the ones which plug into the receptacle and light up indicator lights) As long as the receptacle measures 110-120V between the hot and neutral, and measures 110-120V between the hot and ground, then it is wired correctly and supplying correct voltage with ground reference. To determine if the GFCI is "tripping" or opening the circuit when it should, simply press the test button. If it doesn't trip, (or reset correctly with the reset button) replace the device.
You can't "convert" a 120V receptacle into a 240V receptacle.A proper new 240V branch circuit complete with correctly sized circuit breakers, wiring and socket outlet is required.For more information see the Related Question shown below.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.
Yes, a 130 watt fan can be plugged into a 120 volt receptacle. The current draw will be I = W/E, Amps = Watts/Volts = 130/120 = 1.08 amps.
On the three prong 240 v receptacle there shouldn't be a neutral because it's not needed. Should be two hots and the ground and tuck neutrals in box.
To change 120v to 240v safely and effectively, you will need to install a step-up transformer. This device will increase the voltage from 120v to 240v while maintaining electrical safety. It is important to follow all manufacturer instructions and consult with a qualified electrician to ensure proper installation and operation.