cable size for 90 amps 3 phase 440 v

<<>>

A #3 copper conductor with an insulation factor of 75 or 90 degrees C is rated at 100 and 105 amps respectively.

If this feeder is for a motor connection the wire size has to be increased to 125% of the full load amps of the motor.

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Natural Sciences

How many wires come in from the weather head?

If single phase - 2 wire service &gt; two wires If single phase - 3 wire service &gt; three wires If three phase - 3 wire service &gt; three wires If three phase - 4 wire service &gt; four wires US residential service is usually single phase 3 wire service: Two hots and neutral.


How many watt generator to run a 150 amp service?

You will need a 50 kW generator for a single phase 120/240 volt service.


How much more power does three phase produce?

Single-phase and three-phase can both produce as much power as required if they are correctly designed. Three-phase is used for transmitting power over distances because more power can be transmitted for a given amount of wire. Take three single-phase supplies each transmitting 10 kVA as an example. They use 6 wires in total. Now make them peak out of step, 120 degrees apart in phase. Next, connect the neutral wires together at each end. It will be found that no current is flowing in the neutral wires, so they can be removed. Therefore you are transmitting the same 30 kVA using half the amount of wire by using the 3-phase system. Each live wire acts as the return wire for the other two live wires. This is important when transmitting power for many miles, when the wire is a significant cost.


How many wires are in a 3 phase circuit?

A ground, or earth, conductor is never included in the conductor count. So, a three-phase, three-wire, system has three line conductors, whereas a three-phase, four-wire system, has three line conductors and a neutral conductor.


How many wires are used for a 460 volt circuit breaker?

If the load is single phase and the load requires 460 volts to operate, then two conductors will be needed and they will connect to a two pole breaker. If the load is three phase and the load requires 460 volts to operate, then three conductors will be needed and they will connected to a three pole breaker. The sizing of the wires will depend upon the current that is drawn by the loads.

Related Questions

How many wires come in from the weather head?

If single phase - 2 wire service &gt; two wires If single phase - 3 wire service &gt; three wires If three phase - 3 wire service &gt; three wires If three phase - 4 wire service &gt; four wires US residential service is usually single phase 3 wire service: Two hots and neutral.


How many wires in a single phase motor?

There should be 2 or 3 wires. A hot, a neutral and sometimes a ground.


How many earth wires are required for single phase motor?

There is only one ground wire needed on any motor, single or three phase.


How many single phase can you run on a 100amp 3 phase?

You can divide a three phase service into (3) single phase circuits providing you have a 4th neutral wire.


How many wire or core in three phase electrical connection and single-phase electrical connection?

A single-phase cable will have a line and a neutral conductor and, possibly, but not necessarily, an earth (ground) conductor. A high-voltage three-phase cable will have three line conductors. A low-voltage three-phase cable is likely to have three line conductors and a neutral conductor.


What is the difference between 1 2 and 3 phase?

The main difference between single-phase and three-phase power systems is the number of conductors or wires used to distribute electrical power. Single-phase systems have one live wire and one neutral wire, while three-phase systems have three live wires and one neutral wire. Three-phase power is often used in industrial settings for its ability to provide a more stable power supply and handle higher loads more efficiently compared to single-phase power.


In single phase 1 TR equals how many KW?

1TR = 3.5KW in Single phase and 1.2KW in 3-phase


A three phrase circuit has how many hot wires?

Three wires carry the three phase energy.


How many wires are there in 120 volt single phase power and how are they marked?

Verify wiring layouts by making measurements, before connecting and/or energizing equipment. A 120V single phase 2 wire should have one hot wire, a 230V single phase 2 wire should be assumed to have two hot wires, and a 230V single phase 3 wire also should have two hot wires.


How many wires do you need if you are stepping up single phase 120-240V to 480volts?

Five wires. Two on the primary side, connected to each 120V leg, giving a primary voltage of 240V. Two on the secondary side, one connected to neutral, and the other the new 480V hot. One connecting the frame of the transformer and the box containing it to ground. Note: you will only get one phase power out of this configuration - to get three phase output, you need three phase input, three transformers, and a lot more wires.


How many watt generator to run a 150 amp service?

You will need a 50 kW generator for a single phase 120/240 volt service.


How many phases contains a single substance?

A single substance has one phase.