unbalance voltage supply

resistance between phase unbalance

joints of coil loose

winding short with body

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Natural Sciences

How do you use a one phase motor in place of a three phase motor?

To use a single/one phase motor instead of a three phase motor is possible if you have a three phase power supply as you will only need to tap one of the three phases together with neutral and an earthwire, however to use a three phase motor instead of a single phase will require the provision of three phase power supply.


Can a single phase motor be wired to a three phase soft start?

No, a single phase motor cannot be directly connected to a three phase soft start. A single phase motor requires a single phase power supply, while a three phase soft start is designed for three phase motors. Using the correct soft start for the motor type is essential for proper operation and protection of the equipment.


How many poles are required on motor starters for the following motors a240-volt single-phase induction motor b440-volt three-phase induction motor?

For a 240-volt single-phase induction motor, a two-pole motor starter is typically required, as it connects to the two live conductors of the single-phase supply. For a 440-volt three-phase induction motor, a three-pole motor starter is needed, as it connects to the three phases of the three-phase supply.


Why do ionic crystals conduct electric currents in the liquid phase or when dissolved in the water but do not conduct electric currents in the solid phase?

because when the ions can move around freely, they can conduct electricity better


Can a 240 volt single phase motor be supplied with one phase until the other phase is closed without harming the motor?

It is not recommended to supply a 240 volt single phase motor with only one phase until the other phase is closed. This can cause imbalanced current flow, leading to motor overheating and potential damage. It is best to provide both phases simultaneously to ensure proper operation of the motor.

Related Questions

What is the maximum current unbalance of a 3 phase motor?

No standard prescribes permitted unbalance in current for induction motors. IEC 892/2002 however, specifies permitted unbalance in voltage as 1% at the motor terminal. It is deduced that 1% unbalance in voltage will result in 6% to 9% unbalance in current. This is, therefore, grid caused activity. However, there are load related activities, such as parallel connected single phase loads or shunt capacitors that may also influence unbalance in current across the main contactor. In large motors, sometimes, unbalance in current can be seen if the air-gap eccentricity is seen. In such cases the PF in 3 phases will be unbalanced.


Core balance ct?

CBCT used to protect the motor winding from unbalance load it is install on the cable ,in normal balance conditions the sum of the three phase current is zero so secondary current of the ct also zero .when ever unbalance occurs then this unbalance current will flows through the ct then relay sense and trip motor


Why three phase induction motor has uniform torque?

The 3-phase currents in the 3 coils of an induction motor will produce a steady rotating magnetic field.


Disadvantages of 3 phase induction motor?

One of the disadvantages of the 3 phase induction motor is that it requires a three wire supply. The other disadvantage is that the 3 phase induction motors have poor starting torque and high have in the rush currents.


What is an acceptable difference in resistance between phases on a 3 phase motor?

The currents between legs of a three phase circuit should be within about 10% of each other.


Should all three phases of 3 phase motor are to be equal on no-load and load conditions?

Ideally all three phase currents will be equal. There may exist some voltage imbalance from the power source, which will result in unequal currents.


How does mpcb work?

The basic working principle is similar to all other circuit breakers.• Thermal protection is used to guard the electric motor against overload. It is based on an expanding and contracting contact that disconnects the motor if excessive current is detected. It is very important to know that thermal protection has a delayed response, to allow the high inrush currents when a motor starts. However, if the motor is unable to start for some reason, thermal protection will trip in response to the extended inrush current.• Magnetic protection is used when there is a short circuit, line fault, or other high current electric fault. Unlike thermal protection, magnetic protection is instantaneous, to immediately disconnect the dangerous fault currents.• The main difference between the MPCB and other circuit breakers is that the MPCB can provide protection against phase unbalance and phase loss. Three-phase circuit motors require three live conductors with balanced voltages in order to operate effectively. An unbalance of more than 2% will be detrimental to the motor's service life. If one of the phase voltages is suddenly lost, the effect is even more damaging because the motor will keep on running with only two phases. The motor protection circuit breaker is capable of detecting these conditions by measuring the differences among phase voltages, and disconnects the motor immediately when they occur. It is important to note that phase current unbalance is normal in three-phase systems that power separate single-phase loads, but is unacceptable when the three-phase circuit powers an electric motor.• MPCBs are also equipped with a manual interruption mechanism, allowing disconnection of electric motors for replacement or maintenance.Motor protection circuit breakers are available in a wide variety of current ratings, and one of their best features is that many models allow the current rating to be adjusted. This means that the same MCPB can be configured to protect motors of different capacities.


Why do you connect a capacitor with an Ac motor?

The capacitor is used to create a second phase from the single phase power source and it is the interaction between these two phases that causes the motor to turn.


Why neutral not conect in 3phase motor?

A 3 phase motor does not require a neutral conductor because the impedances that make up the stator coils are of equal magnitude and it is what is known as a balanced 3 phase load. If the loads of a wye connected 3 phase system were unbalanced, i.e. the load currents in each of the 3 phases are different, then the unbalanced currents would require a return path to the service transformer via a neutral conductor. The neutral conductor is the transformer centre tap and is usually earthed locally. ANOTHER ANSWER The impedance of each phase winding of a three phase motor is identical (we call it a 'balanced load'). For a star (wye) connected motor, the phasor sum of three identical phase currents is zero, so no current will flow through a neutral, so a neutral isn't required. For a delta-connected motor, there is no provision for a neutral.


Is single phase connection enough for 18KW motor?

Typically, an 18KW motor would be too large to be single phase because then the windings' conductors will be too large inorder to carry such high currents. I,myself,don't think such a motor exist since a cheaper 3phase motor could be used instead.


What causes 3 phase motors to draw current in common leg?

Three-phase motors can draw current in the common leg due to an imbalance in the phase currents, often caused by unequal loads on each phase or faults in the motor windings. Additionally, issues like phase loss, improper connections, or variations in supply voltage can lead to increased current draw in the neutral or common leg. This condition can result in overheating and reduced efficiency, potentially damaging the motor if not addressed promptly. Proper monitoring and balancing of the load across phases are essential for optimal motor performance.


What happens if 3 phase supply is given to stator and rotor both in a induction motor?

its impossible to give suppy to rotor of an induction motor,because of it a closed path for circulating currents.