When a capillary tube of sufficient length is dipped into a liquid, the liquid rises or falls within the tube due to capillary action, which is the result of adhesive forces between the liquid and the tube's walls, and cohesive forces within the liquid itself. The height to which the liquid rises or falls is determined by the tube's diameter, the liquid's properties (such as surface tension and viscosity), and the interaction between the liquid and the tube material. This phenomenon is commonly observed with water in narrow tubes and is essential in various biological and engineering applications.

User Avatar

AnswerBot

2mo ago

What else can I help you with?

Related Questions

How do net hydrostatic pressure and net osmotic pressure each change along the length of a capillary?

Net hydrostatic pressure decreases along the length of a capillary due to resistance and filtration of fluid out of the capillary. In contrast, net osmotic pressure remains relatively constant along the capillary length, as proteins and solutes that contribute to osmotic pressure do not leave the capillary as easily.


What are the essential steps for placing a solid sample in a capillary tube?

The essential steps for placing a solid sample in a capillary tube are: 1. Crush the solid sample into a fine powder. 2. Use a spatula to carefully transfer the powder into the capillary tube. 3. Use a tamper or glass rod to compact the sample down the length of the tube for accurate measurements.


What is the formula between length of mercury level and temperature in degree celsius?

There is none. In the case of a thermometer, it will depend on the relative dimensions of the bulb and the capillary tube.


What happen to resistance if length is increased?

it increases


Is a capillary tube a metering device?

Yes, a capillary tube is considered a metering device. It regulates the flow of fluids, particularly in refrigeration and air conditioning systems, by providing a precise, constant flow rate based on its diameter and length. The capillary tube creates a pressure drop as the fluid passes through, helping to control the refrigerant flow to the evaporator. Its simplicity and effectiveness make it a common choice for low-capacity systems.


Explain the capillary tube type refrigerant control?

capillary tube are classified under fixed oriffes metering device it is thin and long inorder to control the refrigerant pressure and temperature not to evaporate ontheir way unitl it reach the evaporator.


What is the purpose of the short length of broken capillary tube used in the determination of boiling point?

The short length of the broken capillary tube in boiling point determination serves to ensure that the liquid inside is exposed to both the heat source and the atmospheric pressure effectively. This design allows for a quicker response to temperature changes, enabling the observer to better detect the moment when the liquid begins to boil. Additionally, the short length minimizes the risk of liquid being trapped, which could lead to inaccurate readings. Overall, it aids in achieving a precise measurement of the boiling point.


Why is a capillary tube thought of as a dry-type?

The Capillary tube metering device is used primarily on small fractional-horsepower refrigeration systems that have relatively constant evaporator heat loads. These systems are hermetically sealed, leak free systems with dry-type evaporators that use a minimum of refrigerant. The capillary tube metering device is a fixed bore device, itcontrols refrigerant flow by pressure drop.


Why is the glomerular capillary bed unusual?

unlike other capillaries glomerulus is connected to arterioles on both sides.It's pressure is higher than that of other capillaries and remains almost constant throughout the length of the capillaries.


Which capillary tube can i use for an 404A freezer?

For a 404A freezer, you typically want to use a capillary tube that is suitable for refrigerants with a similar pressure and temperature profile. Commonly, a capillary tube with a diameter of around 0.8 to 1.2 mm and a length that matches the system's requirements (usually between 2 to 4 meters) is used. Ensure the tube material is compatible with HFC refrigerants like R-404A to prevent leaks or failures. Always consult the manufacturer's specifications for precise requirements.


What will happen to length of a simple pendulum if its time period is doubled?

time period of simple pendulum is dirctly proportional to sqare root of length...


What would happen to the length of the day if earth took 40 hours to rotate?

In that case, the length of the day would also be approximately 40 hours.