208 voltage star refers to a three-phase electrical system where the voltage between any two phases is 208 volts. This type of system is commonly used in commercial and industrial applications to power machinery and equipment. Voltage configurations such as 208Y/120V or 208/120V are typical examples of 208 voltage star systems.
No, 230 and 208 are not the same as 220. 230 and 220 are close in value but not identical, while 208 is a different voltage level. It's important to ensure the correct voltage is used when operating electrical equipment to prevent damage or safety hazards.
To convert amps to kVA, you use the following formula: Amps = (kVA x 1000 / voltage) / 1.73
On three phase 208 volts one leg does not have the potential of 208 volts. It takes two legs to provide the 208 volts. The potential is across AB, BC and CA. Voltage to the grounded neutral A-N, B-N and C-N will produce a potential of 120 volts. In a wye configured secondary three phase four wire you have the potential of 120/208 volts.
Yes. This is the same standard. The terms 208 and 220 mean the same thing, much like household voltage is sometimes called 110 or 120.
The watts is the volts times the amps So 208 x 50 watts, or 10.4 kW.
No. A 277 volt ballast needs the correct voltage to operate. The 277 voltage is derived from the star point voltage of a 480 volt three phase system (277/480). The 208 voltage is a three phase line voltage whose star-point voltage is 120 volts (120/208).
The voltage requirement for the air conditioning unit model 208/230 is 208 to 230 volts.
The equipment requires a voltage of either 208 or 230 volts.
122/208
From line-to-line (any two of the three leads) voltage or 'line voltage', the voltage is 208 V. The line-to-neutral (one of the three leads and the neutral conductor), or 'phase voltage', is 120 V.
208 is a three phase wye connection voltage. To obtain the each individual coil voltage the 208 is divided by 1.73 which equals to 120 volts. Hence you have 3 phase 208 voltage on the phase legs and 120 volts to the wye point which is grounded. This same formula is used on any 3 phase system. 600/347, 480/277, 208/120.
Yes. Usually can be found in commercial establishments.
No a 208 volt outlet does not need a neutral. 208 volts is the line voltage between any two legs of a three phase 208 volt system.
No, 230 and 208 are not the same as 220. 230 and 220 are close in value but not identical, while 208 is a different voltage level. It's important to ensure the correct voltage is used when operating electrical equipment to prevent damage or safety hazards.
The Physics of Star Trek has 208 pages.
To convert amps to kVA, you use the following formula: Amps = (kVA x 1000 / voltage) / 1.73
You don't. The cook top was designed to operate on 208 volts. This is the voltage needed to get the elements up to their rated wattage to do the cooking. Higher wattage appliances do not operate on the lower voltage because of the size of the wire that is needed to feed the appliance.