one and a half breaker scheme the same as N-1 scheme. means if you have two BUS you 3 breakers each bay between it protecting your 2 connected loads or transmission lines. meaning if fault detected in a particular line only two breakers will trip isolating the faulted line and will not affect the adjacent line or load.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Natural Sciences

Can you use two 15 amp single pole breakers in place of a double pole 30 amp breaker?

Yes. An everyday occurrence of this circuitry is in your kitchen counter split receptacles. The top half of the receptacle is a 15 amp circuit and from the same breaker the bottom half of the receptacle is another 15 amp circuit. A two pole single handle breaker is a common trip. If one of the circuits fed from the breaker faults the other connected circuit will shut off also. If you are talking about slot position in a breaker panel, you can remove the two pole breaker and install two single pole breakers.


A GFCI device in a breaker is intended to?

A GFCI device in a breaker is intended to trip the breaker open when a ground fault is sensed in the circuit that the breaker is protecting.


If you blew a fuse in your house but the breaker does not show a blown fuse you still have no power to half your house what next?

If it is half the house, that implies the main breaker or the line coming in. Sometimes, double breakers will trip one of them and not the other. It looks like it is still on. Try flipping the breaker off and back on. If you feel comfortable doing it, open up the panel and check each breaker to see if current is getting through them. Just a two prong test light will tell you this. Start on the main, it may be that one of the lines coming in is dead. Looking at the question, you blew a fuse but the breaker does not show a blown fuse. You shouldn't have both in the same circuit. If you have screw in fuses there should be 2 large Buss fuses at the top of the panel. One of these could be blown. These have to be checked with a tester, there is no way to tell just by looking.


What is one half breaker scheme used for 400220kv substation?

a method of interconnecting several circuits and breakers in a switchyard so that three circuit breakers can provide dual switching to each of two circuits by having the circuits share one of the breakers, thus a breaker and one-half per circuit; this scheme provides reliability and operating flexibility, and is generally used at 500 kV when more than five lines terminate in a substation.


When installing a circuit breaker do you size the breaker to correct wire size or the device its controlling?

When installing a circuit breaker, you size the breaker based on the wire size. The breaker should be matched to the ampacity of the wire to ensure proper protection against overloads and short circuits. The device being controlled by the breaker is not a determining factor in sizing the breaker.

Related Questions

What is one and half breaker system in electrical lines?

One and half breaker system is an improvement on the double breaker system to effect saving in the number of circuit breakers. For every 2 circuits, 1 spare breaker is provided: Two feeders are fed from two buses via their associated circuit breakers and these two feeders are coupled by a third circuit breaker which is called tie breaker. During failure of any of the two feeder breakers, the power is fed via the breaker of the second feeder and main breaker (tie breaker).


What is the take up on a half-inch breaker?

do you mean bender? If so, 5"


How long of a lunch break did a coal breaker get?

half an hour till Christmas


What caused half the house to lose power?

The power outage in half of the house was caused by a blown fuse or a tripped circuit breaker.


Why does Half of the electrical box works other half doesn't?

One side of main breaker is broke. One line to the house is open.


Half of 436 is 217.5--why only 216 votes needed?

The Vice President casts the tie breaker.


What is windbreaks?

A win breaker is a fart because when you fart or release methane gas from your anus you are splitting the win in half see


Why is there a power outage in half of the house when the breaker has not tripped?

A power outage in half of the house without a tripped breaker could be caused by a faulty connection in the electrical wiring, a damaged outlet or switch, or a problem with the electrical panel. It is important to have a qualified electrician investigate and repair the issue to ensure safety and restore power.


What could be the cause of a power outage affecting only half of the house?

A possible cause of a power outage affecting only half of a house could be a problem with the electrical wiring or a tripped circuit breaker in the electrical panel. It is recommended to check the circuit breaker first and contact a qualified electrician if the issue persists.


Can you use two 15 amp single pole breakers in place of a double pole 30 amp breaker?

Yes. An everyday occurrence of this circuitry is in your kitchen counter split receptacles. The top half of the receptacle is a 15 amp circuit and from the same breaker the bottom half of the receptacle is another 15 amp circuit. A two pole single handle breaker is a common trip. If one of the circuits fed from the breaker faults the other connected circuit will shut off also. If you are talking about slot position in a breaker panel, you can remove the two pole breaker and install two single pole breakers.


Is there a square d with 2 pulls that will replace a single pull that is one half inch wide as you are out of room in your box?

Yes, Sq D makes a tandem mini breaker that will fit into a standard Sq D breaker slot.


What is the torque for the half shaft nut on 1997 Chevy Venture?

Tight......like 200ftbls tight I get a long breaker bar and stand on it a touch.