answersLogoWhite

0

In a three phase system, connected wye, neutral is the common return, and it is grounded. In a delta connection, there is no neutral.

User Avatar

Darrin Kozey

Lvl 10
2y ago

What else can I help you with?

Related Questions

Why do you find line to neutral capacitance in a 3- Ø system?

In a three-phase system, line-to-neutral capacitance is important because it helps to balance the system and mitigate voltage fluctuations. It provides a return path for capacitive currents, which can improve power factor and reduce losses. Additionally, understanding line-to-neutral capacitance is essential for equipment protection, ensuring that devices can handle potential differences safely. This capacitance also plays a role in harmonic distortion management, enhancing overall system stability.


What significance has a power factor in an unbalanced system?

A three-phase 'unbalanced' system refers to the load, as the supply voltages are unaffected by load. So the phase-angle and, therefore, the power factor of each phase will be different -i.e. there will be three different power factors.


What is the role of a transformer in a neighbourhood?

High voltage(23000vac) is delivered to your community then stepped down(240vac 2 phase 120v to neutral) to allow use of common household appliances.


Why is star connection used in a three phase transformer?

The power of all three phases can be transmitted on three conductors.A star connection, as opposed to a delta, provides a grounding reference. Also, for ground faults on the secondary (assuming no delta third winding, or source third winding) will be a direct ratio similar to phase faults, instead of 57%. Another reason is to avoid the inherent phase shift involved in a delta/star configured transformer.Another AnswerA 'star-connected' secondary is the standard European connection for a three-phase distribution transformer, as it provides a line voltage of 400 V together with a phase voltage (i.e. line to neutral) of 230 V.


What are three system of the body?

The nervous system, circulatory system, and skeletal system make up the three main systems of the body. Each has a special role in maintaining one's life.


Bulgaria's role in WW1?

to be neutral


The heavy bombardment phase of the solar system lasted?

The heavy bombardment phase of the solar system lasted from about 4.1 to 3.8 billion years ago. During this period, the inner planets, including the Earth, experienced intense impacts from leftover debris in the solar system. This phase played a crucial role in shaping the surfaces and atmospheres of these planets.


When did Eclipse Phase - role-playing game - happen?

Eclipse Phase - role-playing game - happened on 2009-08-23.


What is the role of IPA in mobile phase buffer?

In mobile phase buffer, IPA (isopropyl alcohol) can be used to adjust the polarity of the solvent system. It can help improve peak shape and resolution by altering the elution strength of the mobile phase. IPA is commonly used as a modifier in reverse-phase liquid chromatography to optimize separations.


Describe phase three of the International Space Station program?

Phase three of the International Space Station program, known as the utilization phase, focuses on conducting research in various scientific fields like biology, astronomy, and physics. This phase aims to maximize the utilization of the space station for scientific experiments and technology demonstrations to benefit humanity on Earth. International collaboration and partnerships play a significant role in this phase to advance scientific discoveries and foster space exploration.


Indias role in countribution of nam?

India was neutral.


What are the key differences between the adversarial system and the inquisitorial system in legal proceedings?

In the adversarial system, two opposing parties present their cases to a neutral judge or jury who decides the outcome. In the inquisitorial system, the judge takes an active role in investigating the case and gathering evidence.