That depends on the light and the amount of amperage the fixture/bulb is calling for. In a household you would find #14 or #12 gauge wire for lighting fixtures. In some commercial facilities you may find #10 guage wire being used, a good example of that would be parking lot fixtures.
hawt
For 14/2 NM cable, a 14 AWG equipment grounding conductor is used.
Fuses or breakers are used to protect the conductor to the load. A #14 wire conductor is rated for 15 amps. Most home circuitry is done with #14 wire. The minimum size breaker in an electrical panel is 15 amp so it looks like a 15 amp fuse or breaker can be used for a 100 watt light bulb.
When utilizing the volume deduction permitted for fittings, you need to ensure that the conductor size allows for a safe and efficient flow of electricity without exceeding the maximum fill capacity of the conduit. It's recommended to consult with the National Electrical Code or a qualified electrician to determine the appropriate conductor size based on the specific application and code requirements.
For a 100 amp panel, a #4 copper or #2 aluminum conductor would typically be used as a neutral conductor. It's important to consult local electrical codes or a licensed electrician to ensure compliance with regulations and safety standards.
The equipment grounding conductor table provides information about the size of the grounding conductor needed based on the type and size of the electrical equipment being used.
The equipment grounding conductor size chart provides information on the recommended size of the grounding conductor based on the type and size of the electrical equipment being used. This helps ensure proper grounding and safety in electrical systems.
The ground conductor size chart provides information on the recommended size of the ground wire based on the electrical load and the type of wiring system being used.
Clarence W. Hansell is credited as the inventor of the light conductor, also known as the fiber-optic cable, which is used for transmitting digital data.
hawt
A conductor fill chart is used to determine the appropriate size of a conductor for a specific electrical application by providing information on the maximum number of conductors that can be safely installed in a conduit or raceway. This helps ensure that the conductor size chosen can handle the electrical load without overheating or causing other safety issues.
A lemon can power a light bulb because of the acid in it. The acid is used as a conductor and powers the lemon.
hawt
Wood can not let a light bulb light up because wood is a very poor conductor of electicity. A better conductor would be types of metals such as copper or gold, which is used in many electronics.
The size of a current is determined by the voltage applied, the resistance of the circuit, and Ohm's Law (current = voltage / resistance). The type of conductor material used, the temperature, and the cross-sectional area of the conductor also affect the size of a current.
For 14/2 NM cable, a 14 AWG equipment grounding conductor is used.
hawt