answersLogoWhite

0

The Voltage produced by the generator will be like 3 sets of your home's voltage (assuming we're looking at an outlet and not the 220V at the brkr box).

Each phase (sinusoidal wave) will be separated by 120 degrees, so when the 1st phase starts the 2nd phase will start 1/20th of a second later. The 3rd phase then starts 1/40th of a second later, and the 1st phase starts again 1/60th of a second later which is the beginning of the second set of sin waves. This of course is based on the N. American Frequency of 60 hertz which is 60 cycles (waves) per second.

Answer

For a three-phase, three-wire, system the line voltages will be identical to the phase voltages.

For a three-phase, four-wire, system the line voltages will be 1.732 times the value of the phase voltages.

User Avatar

Wiki User

11y ago

What else can I help you with?

Continue Learning about Natural Sciences

What is phase voltage and line voltage in star connection?

The conductors that connect a three-phase supply to its load are called 'line conductors' or, more simply, 'lines'. The individual generator stator windings, transformer winding, or loads are called 'phases'. Lines and line terminals are identified by colours, letters, numbers, or combinations of letters and numbers. For example, A-B-C. Phases are identified by using the letters assigned to the line terminals between which the phases are connected, e.g A-B, B-C, and C-A. Voltages measured between lines ('line-to-line') are termed 'line voltages', and currents that pass through the lines are called 'line currents'. Voltages measured across a generator's windings, transformer windings, or individual loads, are called 'phase voltages', and the currents that pass through these are called 'phase currents'. For a three-phase, three-wire, system, the phase- and line-voltages are numerically-equal to each other. For a three-phase, four-wire, system, the line voltage is 1.732 times larger than the phase voltage.


Is transmission voltage a phase to phase voltage or a phase to ground voltage?

Phase to Phase voltageCorrection to the above answer:There is no such thing as a 'phase-to-phase' or 'phase-to-ground' voltage. The correct terms are 'line-to-line' (or 'line voltage') and 'line-to-ground' (or 'phase voltage'). Transmission-line voltages are line-to-line (or 'line') voltages.


How many volt each phase in three phase?

600 volts between any two wires. The phase has nothing to do with voltages, only current relationship.


Why is phase voltage not twice line voltage?

Line to line voltage is not the same as line to neutral voltage because line voltages are 120 degrees apart. They are related by: Line to neutral voltage * tan (120 degrees) = Line to neutral voltage * 1.73.Additional CommentFor delta-connected systems, the line voltage is the same as the phase voltage.For wye-connected systems, the line voltage is larger than the phase voltage by a factor of 1.732. The reason for this is as follows:Because any two phase voltages are displaced from each other by 120o, they must be added vectorially, not algebraically, to find the line voltage. As the above answer points out, this means that the relationship between the two is the square-root of 3, or 1.732.


The phase angle between voltage and current in an a c circuit through a pure capacitance is?

90 degrees. In an AC circuit with a pure capacitance, the current leads the voltage by 90 degrees. This is because the current in a capacitor is proportional to the rate of change of voltage across it, leading to this phase relationship.

Related Questions

What is the relationship between the current and voltage in a pure inductive circuit?

In a pure inductive circuit, the relationship between current and voltage is such that the current lags behind the voltage by a phase angle of 90 degrees. This means that the current and voltage are out of phase with each other, with the current reaching its peak value after the voltage has reached its peak value.


Can the star point of a 400 volt three phase generator be grounded to produce 240 volts?

A 400/230-V three-phase generator hase three line terminals, together with a neutral terminal. The line voltage (i.e. the voltage between any pair of line terminals) is 400 V, while the phase voltage (i.e. the voltage between any line terminal and the neutral terminal) is 230 V.


Can a diesel generator for elevators run on single phase?

If the elevator has a single-phase motor, the diesel generator can also be single phase provided the voltage and VA ratings are compatible.


What is the relationship between impedance phase angle and the behavior of an electrical circuit?

The impedance phase angle in an electrical circuit indicates the relationship between voltage and current. A phase angle of 0 degrees means voltage and current are in phase, while a phase angle of 90 degrees means they are out of phase. This affects how the circuit behaves, influencing factors like power consumption and efficiency.


How many amps for 1010 KVA generator per phase?

To answer this question the voltage of the generator must be given.


How many kva is needed to draw 550A in a 3 phase generator?

The voltage of the generator needs to be stated to give an answer.


How do you wire a three phase four wire generator for single phase output?

In a three phase four wire system - voltage between any one phase and the neutral is single phase. Hence the single phase equipment or load between any one phase and the neutral.Another AnswerA single-phase load can be connected either between any line conductor and the neutral conductor, or between any pair of line conductors. The choice is dependent on the voltage rating of the load, which must match either the phase voltage (line-to-neutral) or line voltage (line-to-line) -these values will be indicated on the machine's nameplate.


What is the phase relationship resistor and voltage?

inversily propsanational


Does kva equal voltage x current x 1.73 for a 3 phase generator?

Yes, but only for balanced loads (current in all three phases the same value). The voltage value used is the phase to phase voltage.


How match 2 phase line voltage between them?

To match 2 phase line voltage it has to be the same voltage.


What size of wire to use for 1015 kva ac generator?

To answer this question a voltage must be given to find the current output. Also whether the generator is three phase or single phase.


What generator is suitable for a 2 HP single phase motor?

Any single-phase a.c. generator producing more than 2.5 HP or 2 kW - at the required voltage.