For a 45 amp circuit breaker, you typically need to use 6 AWG copper wire or 4 AWG aluminum wire, according to the National Electrical Code (NEC). The choice between copper and aluminum depends on the specific application and local code requirements. Always ensure to check local electrical codes and regulations, as they can vary by region. Additionally, proper installation and consideration of factors like wire length and ambient temperature are crucial.

User Avatar

AnswerBot

3w ago

What else can I help you with?

Continue Learning about Natural Sciences

14 gauge wire can be on what size circuit breaker?

A 14 gauge wire is typically used on a 15 amp circuit breaker. It is not recommended to use a larger circuit breaker with a smaller wire size as this can create a fire hazard.


What size wire and breaker do you need for a 5000 watt garage heater?

Look on the heater and see what amps it is pulling. That will determine the wire size and breaker size. It must be on a dedicated circuit. 15 amps = AWG # 14 wire with 15 amp breaker 20 amps = AWG # 12 wire with 20 amp breaker 30 amps = AWG # 10 wire with 30 amp breaker 40 amps = AWG # 8 wire with 40 amp breaker


Can a circuit breaker be tripped by using 20 amp sockets instead of 15 amp sockets?

A circuit breaker protects the wires that the devices are connected to. If the devices that are connected to the circuit are 20 amps the wire size should be #12 wire fed from a 20 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. If the devices that are connected to the circuit are15 amps the wire size should be #14 wire fed from a15 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. Putting 20 amp sockets on this 15 amp circuit will work but the circuit is limited to the amount of load that can be plugged in. You will not get the full capacity of the 20 socket because the breaker will trip at 15 amps.


What size wire and circuit breaker is needed for an electric oven 4 wires with rated load of 34.9 amps 220v that is about 100 foot run from the electrical panel?

That would be a 40 amp 220v circuit. Circuit breaker is 40 amps and wire is 8 awg. Should use solid copper wire. Follow oven installation instructions.


What size wire do you need to run to an air conditioner that has a maximum breaker size of 40 amps and a minimum circuit size of 25.3 amps?

You would need to use a wire size that is rated for at least 40 amps to be safe and to meet the requirements of the air conditioner. A common wire size for this application would be 8 AWG copper wire, which is rated for 40 amps.

Related Questions

What size circut breaker for 10-2 wire?

A #10 wire has the capacity for 30 amps. No breaker larger than 30 amps should be used to protect the circuit.


14 gauge wire can be on what size circuit breaker?

A 14 gauge wire is typically used on a 15 amp circuit breaker. It is not recommended to use a larger circuit breaker with a smaller wire size as this can create a fire hazard.


What size wire and breaker do you need for a 5000 watt garage heater?

Look on the heater and see what amps it is pulling. That will determine the wire size and breaker size. It must be on a dedicated circuit. 15 amps = AWG # 14 wire with 15 amp breaker 20 amps = AWG # 12 wire with 20 amp breaker 30 amps = AWG # 10 wire with 30 amp breaker 40 amps = AWG # 8 wire with 40 amp breaker


Can a circuit breaker be tripped by using 20 amp sockets instead of 15 amp sockets?

A circuit breaker protects the wires that the devices are connected to. If the devices that are connected to the circuit are 20 amps the wire size should be #12 wire fed from a 20 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. If the devices that are connected to the circuit are15 amps the wire size should be #14 wire fed from a15 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. Putting 20 amp sockets on this 15 amp circuit will work but the circuit is limited to the amount of load that can be plugged in. You will not get the full capacity of the 20 socket because the breaker will trip at 15 amps.


Should 25 amps breaker be replaced by 20 amps?

For typical residential house wiring 12 AWG wire is required for a 20 Amp breaker. If you change out the breaker for a 25 A breaker you would have to rewire the circuit with 10 AWG. In that case you could up the breaker to 30 Amps. All outlets and switches should be rated at the same voltage and current as the breaker.


Why are electric ranges wired to separate circuit breaker?

As a range is a high current device, the electrical code stipulates that it has to have its own breaker. The breaker protects the wire feeder. An electric range breaker is set to trip at 40 amps. Using a smaller wire that #8 is not allowed as their ratings are below that of the #8 wire. #10 wire rating is 30 amps, #12 wire rating is 20 amps, and #14 wire rating is 15 amps.


What size amp circuit breaker would protect a 12kW boiler?

The breaker protects the wiring not the boiler. 12,000 watts at 240 volts will require 50 amps. So, you will need a 60 amp breaker using AWG# 6 wire on a dedicated circuit.


How do you change wire fuse for circuit breaker?

A circuit breaker does not have a wire fuse in it.


What size wire and circuit breaker is needed for an electric oven 4 wires with rated load of 34.9 amps 220v that is about 100 foot run from the electrical panel?

That would be a 40 amp 220v circuit. Circuit breaker is 40 amps and wire is 8 awg. Should use solid copper wire. Follow oven installation instructions.


Can you upgrade a 15 Amps circuit breaker for a 40 Amp for a 8.5 Watt shower?

Not unless you change the wiring for that circuit. The breaker protects the wiring and if you install a 40 amp breaker on a 15 amp wire circuit you will have a fire in your home.


What size wire do you need to run to an air conditioner that has a maximum breaker size of 40 amps and a minimum circuit size of 25.3 amps?

You would need to use a wire size that is rated for at least 40 amps to be safe and to meet the requirements of the air conditioner. A common wire size for this application would be 8 AWG copper wire, which is rated for 40 amps.


Could you use a 12gauge wire for a 25 amp breaker single pole?

No, a 12-gauge wire is typically rated for a 20 amp circuit. To safely handle a 25 amp breaker, you would need to use a 10-gauge wire. It's important to match the wire gauge to the amperage rating of the breaker to prevent overheating and potential fire hazards.