The exact year that Romex Wire came out is not listed on their website. However, they do say that they have been selling the wire for over 88 years.

I have found the year 1926

User Avatar

Wiki User

11y ago

What else can I help you with?

Continue Learning about Natural Sciences

What was used before romex wire became available?

Before Romex wire became available, cloth-covered wire, knob-and-tube wiring, and armored cable (BX) were commonly used for electrical wiring in residential buildings.


Is that possible to run romex wire to the under ground basement?

No, it is not possible to run Romex wire directly underground in a basement. Romex wire is not rated for direct burial underground and should not be used in this application. Instead, you should use UF-B (underground feeder) cable or conduit with appropriate wiring for underground installations.


What gauge romex for outlets?

Romex is a manufacturer's wire cable trade name, the 10 refers to the size of the wire inside the cable set. A #10 AWG copper conductor with an insulation factor of 90 degrees C is rated for 30 amps.


What wire is commonly used in house wiring?

Romex, All you have to do is go to a hardware store and tell them you need house wire. It comes in a box. I am not sure how many feet. If you are just looking for the gauge, they will know that too.


What is the diff between 14-2 and 14-3 romex wire?

The primary difference between 14-2 and 14-3 Romex wire lies in the number of conductors contained within the cable. 14-2 Romex has two insulated conductors (one black, one white) and a bare ground wire, making it suitable for standard circuits. In contrast, 14-3 Romex includes three insulated conductors (black, red, and white) plus a bare ground, allowing for multi-wire branch circuits and more complex installations, such as three-way switches.

Related Questions

Do you need 3-wire romex to feed bedroom ceiling box by electrical code?

No, you can feed it with a 2 wire Romex + ground. It depends on what is mounted on the ceiling. If it is just a light all you need is 2 wire + ground Romex. However if it is a fan/light and you want to control each one independant of the other you will need to use 3 wire Romex + ground. This is of course if you have 2 seperate switches. You would then connect the red wire to the blue light wire and the black wire to the black fan wire. If you use 2 wire Romex just connect the blue and black fan/light wire to the black wire in the ceiling box.


What are the standard Romex wire colors used in electrical wiring?

The standard Romex wire colors used in electrical wiring are black, white, and bare copper.


Can you mix aluminum wire with romex in a junction box?

No, do not mix aluminum wire with copper wire.


Can you run Romex through a wire mold?

The key is that you don't want to cause over-heating in wire. The answer is you can probably do what you want unless it involves high current and a small cross section in wire mold such that the Romex could generate too much heat. You could always strip out the wires inside the Romex and just run them in the wire mold.


Is romex wire copper or aluminum?

Standard Romex is a three-strand, solid core wire, individually insulated, in a common sheath to make it easier to pull. For a short time, some manufacturers were making romex with aluminum because the cost of copper was so high, but the aluminum wire was not as good as the copper, and the practice was discontinued.


What was used before romex wire became available?

Before Romex wire became available, cloth-covered wire, knob-and-tube wiring, and armored cable (BX) were commonly used for electrical wiring in residential buildings.


Is that possible to run romex wire to the under ground basement?

No, it is not possible to run Romex wire directly underground in a basement. Romex wire is not rated for direct burial underground and should not be used in this application. Instead, you should use UF-B (underground feeder) cable or conduit with appropriate wiring for underground installations.


What gauge romex for outlets?

Romex is a manufacturer's wire cable trade name, the 10 refers to the size of the wire inside the cable set. A #10 AWG copper conductor with an insulation factor of 90 degrees C is rated for 30 amps.


What are the differences between THHN and Romex wires, and which one is more suitable for residential electrical wiring?

THHN wire is a single-conductor wire used for commercial and industrial applications, while Romex wire is a type of electrical cable with multiple conductors used in residential settings. Romex wire is more suitable for residential electrical wiring due to its ease of installation and protection against damage.


Does all romex have a ground wire?

Some older wire does not have a ground. All you can do in that case is use a jumper wire to connect the ground to the neutral.


What wire is commonly used in house wiring?

Romex, All you have to do is go to a hardware store and tell them you need house wire. It comes in a box. I am not sure how many feet. If you are just looking for the gauge, they will know that too.


How to wire a 3-way switch with 14-2 Romex?

To wire a 3-way switch with 14-2 Romex, connect the black wire to the common terminal on one switch, the white wire to the common terminal on the other switch, and the red wire to the traveler terminals on both switches. Connect the ground wires to the switches and the bare copper wire to the ground terminal.