answersLogoWhite

0

In three phase:

I = (three phase VA) / (sqrt(3) x (phase to phase voltage))

for single phase:

I = (single phase VA) / ((phase to neutral voltage))

keep in mine three phase VA = 3 x (single phase VA),

and phase to phase voltage = 1.732 x (phase to neutral voltage)

Therefore the single phase and three phase currents are the same (ie, the three phase currents are the same in all three phases, or balanced).

But don't get available current and available power confused (KVA is not the same as KW).

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Natural Sciences

What is the difference between a single phase and a three phase inverter?

The Single and Three phase refer to Alternating Current electrical power supply outlet system and the corresponding equipment requirements. The single phase system is generally used thepower requirements are low or moderate as for household applications , while the Three phase supply system is used for High power industrial applications. Thenumbers of phases refer to Alternating Current Supply lines which are delivering the power or the sytem requirement of the equipment for operation. Thus a single phase supply cannot operate a three phase equipment or vice versa. However a ThreePhase supply can be used individually as Three different Single Phase supply systems In case of Three Phase systems the electrical supply waveforms are such that at any given instant there is a 120 degree phase difference between any two supply lines , which also results in higher magnitude of supply voltage than the corresponding single phase supply. Now refering to the inverter which is nothing but a device to convert the electrical supply from one source or magnitude ( typically DC from a Battery Bank ) to the required form and Magnitude. Thus it simply generates the equivalent electrical supply either as Singleor Three Phase , which ideally will be the same as available available from the wall outlet


Can different size conductors be used on a three phase supply?

In normal use a 3-phase supply is balanced so that the three phase wires would be of equal size because they carry equal current. When in balance the system draws no current in the neutral wire (if present). In some conditions different currents are taken from a 3-phase supply, for example three houses connected to the different phases will probably take different currents, and in that case the neutral could carry a current up to or equal to that in one of the phase wires. Therefore in supplying a street, the four wires of a 3-phase supply would all be of equal size.


Single phase motor speed is determined by the?

frequency of the power supply it is connected to. The speed of a single phase motor is directly related to the frequency of the alternating current (AC) power supply. As the frequency of the power supply changes, the speed of the motor will also change.


Can a single phase supply be used in a three phase supply?

No, a single-phase supply cannot be directly used in a three-phase system. The voltages and phases are different, so additional equipment such as a phase converter or transformer would be needed to convert the single-phase supply to match the requirements of the three-phase system.


What happen if we do the 3 phase winding in rotor of induction motor and give the 3 phase supply only stator winding?

This is how an induction motor normally works, hence the name. The supply voltage is connected to the stator winding(s) and a current is induced in the rotor. A synchronous motor, on the other hand, will have current supplied to the rotor through slip rings and brushes. The rotor current is generally supplied as DC though, or else rectified in the rotor.

Related Questions

Does DC have a single phase and a three phase supply?

No, there is not. Three phase ,or generally speaking multiphase, circuits are available only for AC (alternating current) systems, because there is no phase shift in DC (direct current) systems. This is because DC power is not sinusoidal (current flows in one direction).


What is the voltage and current for a single phase supply?

240v


Can you run a three phase appliance on 240 volt power supply?

No. You need a 3-phase supply that matches the voltage and current rating of your appliance.


What is the difference between a single phase and a three phase inverter?

The Single and Three phase refer to Alternating Current electrical power supply outlet system and the corresponding equipment requirements. The single phase system is generally used thepower requirements are low or moderate as for household applications , while the Three phase supply system is used for High power industrial applications. Thenumbers of phases refer to Alternating Current Supply lines which are delivering the power or the sytem requirement of the equipment for operation. Thus a single phase supply cannot operate a three phase equipment or vice versa. However a ThreePhase supply can be used individually as Three different Single Phase supply systems In case of Three Phase systems the electrical supply waveforms are such that at any given instant there is a 120 degree phase difference between any two supply lines , which also results in higher magnitude of supply voltage than the corresponding single phase supply. Now refering to the inverter which is nothing but a device to convert the electrical supply from one source or magnitude ( typically DC from a Battery Bank ) to the required form and Magnitude. Thus it simply generates the equivalent electrical supply either as Singleor Three Phase , which ideally will be the same as available available from the wall outlet


Phase difference between voltage and current at resonance?

The power factor is a measure of the phase difference. If they are exactly in phase the PF = 1. If they are 180 degrees out of phase PF = 0.


Is DC three phase system available?

The short answer is no. Here is the longer answer: The concept of "phase" applies only to alternating current. Alternating current consists of a sine wave voltage at a certain frequency (usually 60Hz). When multiple supplies are present they are the same frequency, but offset in phase angle. This means that one supply will reach the peak voltage while another may be at the minimum voltage. In residential and commercial electrical systems, up to three different phases of alternating current are supplied to the house or business. The phase relationship between the three "arms" of the supply is tightly controlled because certain equipment depends on the phase relationship between the supplies. DC (Direct Current) is always at the same voltage. Because it does not vary, it has no frequency and no phase, so you cannot have a 3 phase supply.


A delta connected 3 phase motor, shown above, draws a line current of 24 A from a 400 V supply, If fuse F3 blows, determine the current in each phase winding of the motor.IA = IC = IB=?

For proper working of any 3 phase induction motor it must be connected to a 3 phase alternating current (ac) power supply of rated voltage ...


What is the difference between three phase load and phase supply?

How much current equipments are drawing from three phases (combined or individual) is called three phase load and how much supply we are getting from source is called three phase supply. Ex. In INDIA single phase supply is 220 volt ac with neutral. So in three phase supply all RYB phases should be 220 volts ac with neutral individually. If we calculate with phase to phase than it shoulb be 415 volts ac.


Is house current fit for single or three phase motor?

House current is single phase.AnswerIt depends on the system supplying your residence. Most are single phase, but some, such as here in Cyprus, have a three-phase supply as standard.


What is difference between line current and phase current?

A phase current is the current passing through a phase, whereas a line current is the current flowing through a line.In the case of a balanced delta-connected load, IL = 1.732 IP. In the case of a balanced star-connected load, IL = IP.For unbalanced loads, these relationships don't hold true, and must be individually calculated.


How can you fix the output current of phase angle?

Your question doesn't really make much sense. Phase angle is simply the angle by which the load current leads or lags the supply voltage.


Why is important for three phase supply voltage to be in-phase?

The phase voltages (i.e. line-to-neutral in a 4-wire system, or line-to-line in a 3-wire system) of a three-phase system are displaced from each other by 120 electrical degrees. Each phase voltage, in fact, is rarely in phase with its phase current, as the phase-angle (the angle by which a phase current lags or leads its phase voltage) is determined by the load not by the supply.In general, most loads are resistive-inductive so the phase current usually lags the phase current.So, to answer your question, it's not important that a phase current is in phase with its phase voltage -if that is what you are asking.