It must, of course!: - Because Lambdamax in a Wavelength-Range is defined this way!
The maximum wavelength of absorbance for sodium dichromate typically occurs around 350-370 nanometers (nm). This absorbance is primarily due to the presence of the chromate ion, which exhibits strong UV-visible absorbance characteristics. The specific wavelength can vary slightly depending on the concentration and the solvent used.
If you have a spectrofotometer ( the thing to mesure the absorbance) then play with the setting and use a maximum. this will lay close to your specific absorbance or take the pharmacopea or a MERCK index
Short answer:Using the maximum wavelength gives us the best results. This is because at the peak absorbance, the absobance strength of light will be at the highest and rate of change in absorbance with wavelength will be the smallest. Measurements made at the peak absorbance will have the smallest error.Long answer: It really depends on what is the largest source of error. Taking the readings at the peak maximum is best at low absorbance, because it gives the best signal-to-noise ratio, which improves the precision of measurement. If the dominant source of noise is photon noise, the precision of absorbance measurement is theoretically best when the absorbance is near 1.0. So if the peak absorbance is below 1.0, then using the peak wavelength is best, but if the peak absorbance is well above 1.0, you might be better off using another wavelength where the absorbance is closer to 1. Another issue is calibration curve non-linearity, which can result in curve-fitting errors. The non-linearity caused by polychromatic light is minimized if you take readings at either a peak maximum or a minimum, because the absorbance change with wavelength is the smallest at those wavelengths. On the other hand, using the maximum increases the calibration curve non-linearity caused by stray light. Very high absorbances cause two problems: the precision of measurement is poor because the transmitted intensity is so low, and the calibration curve linearity is poor due to stray light. The effect of stray light can be reduced by taking the readings at awavelength where the absorbance is lower or by using a non-linear calibration curve fitting technique. Finally, if spectral interferences are a problem, the best measurement wavelength may be the one that minimizes the relative contribution of spectral interferences (which may or may not be the peak maximum). In any case, don't forget: whatever wavelength you use, you have to use the exact same wavelength for all the standards and samples. See http://terpconnect.umd.edu/~toh/models/BeersLaw.htmlTom O'HaverProfessor Emeritus
using uv-visible spectrophotometer concentration vs absorbance is plotted and the maximum absorbance of the drug is lambda max of the drug. then after it will decrease. still if needed clarification, refer beer lambert"s law
The UV-visible absorption spectrum of tapentadol typically shows a lambda max wavelength around 274-276 nm. This is the wavelength at which tapentadol exhibits maximum absorbance when exposed to UV light.
The wavelength with the maximum absorbance corresponds to the peak absorption of the compound being analyzed, providing the most accurate and precise measurement. By measuring absorbance at the maximum wavelength, we can ensure the highest sensitivity and specificity in detecting and quantifying the compound of interest.
The wavelength of light is set at maximum absorbance when making a Beer's Law plot because it allows for the most accurate and precise measurement of the absorbance of a sample. This wavelength corresponds to the peak absorbance of the sample, providing the most reliable data for constructing the plot and determining the concentration of the analyte.
If you have a spectrofotometer ( the thing to mesure the absorbance) then play with the setting and use a maximum. this will lay close to your specific absorbance or take the pharmacopea or a MERCK index
The maximum wavelength of absorbance for potassium permanganate is around 525 nanometers. At this wavelength, potassium permanganate exhibits a strong absorption peak due to its characteristic deep purple color. This absorption peak is often used in spectrophotometric analyses to quantify the concentration of potassium permanganate in solution.
A spectrophotometer is typically the most useful equipment for measuring wavelength. It can measure the absorbance or transmittance of a substance at different wavelengths, allowing for the determination of the wavelength of maximum absorbance or transmittance.
Short answer:Using the maximum wavelength gives us the best results. This is because at the peak absorbance, the absobance strength of light will be at the highest and rate of change in absorbance with wavelength will be the smallest. Measurements made at the peak absorbance will have the smallest error.Long answer: It really depends on what is the largest source of error. Taking the readings at the peak maximum is best at low absorbance, because it gives the best signal-to-noise ratio, which improves the precision of measurement. If the dominant source of noise is photon noise, the precision of absorbance measurement is theoretically best when the absorbance is near 1.0. So if the peak absorbance is below 1.0, then using the peak wavelength is best, but if the peak absorbance is well above 1.0, you might be better off using another wavelength where the absorbance is closer to 1. Another issue is calibration curve non-linearity, which can result in curve-fitting errors. The non-linearity caused by polychromatic light is minimized if you take readings at either a peak maximum or a minimum, because the absorbance change with wavelength is the smallest at those wavelengths. On the other hand, using the maximum increases the calibration curve non-linearity caused by stray light. Very high absorbances cause two problems: the precision of measurement is poor because the transmitted intensity is so low, and the calibration curve linearity is poor due to stray light. The effect of stray light can be reduced by taking the readings at awavelength where the absorbance is lower or by using a non-linear calibration curve fitting technique. Finally, if spectral interferences are a problem, the best measurement wavelength may be the one that minimizes the relative contribution of spectral interferences (which may or may not be the peak maximum). In any case, don't forget: whatever wavelength you use, you have to use the exact same wavelength for all the standards and samples. See http://terpconnect.umd.edu/~toh/models/BeersLaw.htmlTom O'HaverProfessor Emeritus
The wavelength of maximum absorbence relates to the color, because the only color that is not absorbed will be the color of the item. For example, plants are green because they absorb red and blue light, and reflect green light.
The maximum absorbance of methyl orange typically occurs at around 464 nm, not 242 nm. At 242 nm, the absorbance may be lower or not significant, as this wavelength is outside the main absorption range for methyl orange. For accurate absorbance values, it is important to refer to specific absorption spectra or experimental data for methyl orange.
The wavelength of 275 nm is used to measure absorbance of caffeine because it corresponds to the maximum absorbance peak for caffeine. By using a wavelength where caffeine absorbs strongly, we can accurately measure its concentration in a sample based on the amount of light absorbed at 275 nm.
Analytical wavelength refers to the specific wavelength of light that is used for analysis in spectroscopic techniques, such as atomic absorption spectroscopy and UV-visible spectroscopy. This wavelength is selected based on the absorption characteristics of the sample being analyzed to provide accurate and sensitive measurements.
using uv-visible spectrophotometer concentration vs absorbance is plotted and the maximum absorbance of the drug is lambda max of the drug. then after it will decrease. still if needed clarification, refer beer lambert"s law
The UV-visible absorption spectrum of tapentadol typically shows a lambda max wavelength around 274-276 nm. This is the wavelength at which tapentadol exhibits maximum absorbance when exposed to UV light.