answersLogoWhite

0

There is a short somewhere in the line. Start at the outlet end and what is plugged into it and work your way back. If it is a GFI breaker, they can be bad and trip as soon as any drain is put on them. I have had them trip as soon as a drill is plugged in without even turning on the drill.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Natural Sciences

If a shunt trip occurs does breaker go to off or trip position?

When a shunt trip occurs, the breaker typically goes to the "trip" position, which indicates that the circuit has been interrupted and the contacts are open. This allows for quick identification of the issue and isolation of the circuit for safety reasons.


When a shunt trip breaker trips does the voltage remain on?

No, it does not have voltage in trip position.


Does a shunt trip breaker work from a dry set of contacts?

Yes, but you need a power source, for the shunt trip coil voltage, in the circuit.


Why would a breaker trip after 30 sec with nothing plugged in to the circuit except the tv that is turned off?

First unplug the TV. Some TVs may still draw current when off, but not enough to cause a breaker to trip. However you still want to make sure you don't fry your TV as you troubleshoot. If there is nothing plugged in to any outlet on the branch circuit and there are no light fixtures the problem is a bad breaker or in the wiring. The ideal is to have an electrician troubleshoot since you can kill yourself while messing with the breaker panel if you don't know what you are doing. Turn breaker off, make sure with a meter that the breaker is no longer hot and remove the wire by unscrewing the lug screw. Do the same for another breaker of the same rating. Hook the first wire removed to the second breaker. Turn on the second breaker. If it doesn't trip the problem is first breaker, and you need to replace it. If the second breaker trips it is the wiring. With the second wire and breaker restored to original connection, leave the first wire disconnected. Measure the resistance with a meter of the disconnected first wire to neutral which are where white wires are connected in panel. If you have everything unplugged there should be an open circuit. If not you need to start disconnecting wires in outlets and fixtures on the branch circuit and determine where the short is. Since breaker stays on for 30 seconds it is likely the breaker since a dead short would trip breaker immediately. The exception would be a short that is causing a current to flow that is very close to the rating of the breaker. If the breaker is good then I suspect you have something plugged in you don't know about.


Will a short circuit cause smoke detectors to beep after resetting the circuit breaker?

If your smoke detector is bleeping you have a serious risk of fire and the circuit breaker must not be reset until the fault that caused it to trip is investigated.

Related Questions

Can a breaker be bad and not trip when there is an electrical overload?

Yes, a breaker can be faulty and fail to trip when there is an electrical overload.


How can I intentionally trip a breaker in a safe and controlled manner?

To intentionally trip a breaker in a safe and controlled manner, you can first identify which breaker controls the circuit you want to trip. Then, turn off all devices connected to that circuit. Next, firmly push the breaker switch to the "off" position, which will trip the breaker. Finally, reset the breaker by switching it back to the "on" position once the issue is resolved.


Can a shunt trip breaker be tripped from to different emergency buttons?

Yes a shunt trip breaker can be activated manually.


What can cause a circuit breaker to trip?

A circuit breaker can trip due to overloading, short circuits, or ground faults.


How do you detect if a shunt trip breaker is malfunctioning?

The way to detect if a shunt trip breaker is malfunctioning is to manually trip the breaker. The shunt is usually wired through a auxiliary relay. Make sure that before you trip the breaker that the load can be shut off without taking a production line etc. off line. Trip the auxiliary relay using a test jumper to activate the relays coil. The breaker's handle will move to mid throw and the load will disconnect from the supply power. If the breaker trips then it is working properly. If the breaker does not trip trouble shoot the circuitry that is used to trip the breaker. Usual problem is an open circuit.


How much does a shunt trip breaker cost?

The cost of a shunt trip breaker depends on the amperage and number of poles the circuit connected to it needs. The cost of the shunt trip over a conventional breaker is substantially more.


What are the breaker ampere trip ratings?

The ampere frame rating for a circuit breaker designates how the circuit breaker should be configured. It also states the trip unit of the amp.


Does the power supplied to trip shunt trip breaker have to be applied momentarily or can it latch?

A shunt-trip breaker trips when voltage is applied to the coil. It does not self-reset when the voltage is removed, the breaker must be reset manually. The trip voltage can either latch or be applied momentarily, but must be de-energized before the breaker will reset.


Can a thermostat cause a breaker to trip?

If it is a line thermostat and it is connected across the line instead of in series with the load then yes it will trip the breaker.


If a shunt trip occurs does breaker go to off or trip position?

When a shunt trip occurs, the breaker typically goes to the "trip" position, which indicates that the circuit has been interrupted and the contacts are open. This allows for quick identification of the issue and isolation of the circuit for safety reasons.


Can a loose wire cause a breaker to trip?

Yes, a loose wire can cause a breaker to trip. When a wire is loose, it can create a short circuit or excessive heat, which can trigger the breaker to trip as a safety measure to prevent electrical hazards.


When a shunt trip breaker trips does the voltage remain on?

No, it does not have voltage in trip position.