answersLogoWhite

0

because otherwise it gives you an incorrect reading. burette measurements are very precise, because you can easily see how many milliliters of substance you are pouring out - air bubbles will interfere with this exact calculation.

User Avatar

Wiki User

16y ago

What else can I help you with?

Continue Learning about Natural Sciences

How do you condition a buret?

To condition a buret, first rinse it with distilled water to remove any contaminants. Then, rinse the buret with the solution you will be using by filling it partially, swirling it to coat the inner surfaces, and then draining it completely. This ensures that the inner surfaces are coated with the solution, reducing the risk of dilution from residual water. Finally, fill the buret with the solution to the desired level, ensuring there are no air bubbles in the tip.


How a buret is filled up?

To fill a buret, close the stopcock at the bottom, pour the solution into the top of the buret, open the stopcock slightly to allow air bubbles to escape, and then close the stopcock once the solution reaches the zero mark on the scale. Adjust the meniscus by gently tapping the buret if needed.


How would air bubbles in the tip of a buret of Na OH effect the efficiency number of antacids?

The final reading is then taken including the bubbles. So if the bubbles are 2 mL and your buret reads 12 mL. It seems like there is 12mL added, but the bubble was not taken into account. So you only pipetted 1o mL yet the bubble made it seem like 12.


What happens when you forget to remove the air bubble from the tip of the buret that contains NaOH in a titration?

If you forget to remove the air bubble from the buret tip, it can affect the accuracy of the titration results. The air bubble can displace some of the liquid in the buret, leading to an incorrect volume measurement of the NaOH solution delivered. This can result in errors in the determination of the unknown concentration of the other solution being titrated.


Why is it necessary to remove all the air in IV tubing?

Removing all the air from IV tubing is important to prevent air embolisms, which can block blood vessels and be life-threatening. The air bubbles can also affect the accuracy of medication delivery.

Related Questions

Should you dispense a buret rinse through the top or the tip?

You should dispense a buret rinse through the tip to ensure proper cleaning and prevent air bubbles from forming in the buret. This method also helps to remove any residual liquid or contaminants from the buret.


Removing Air bubbles?

To remove the air bubbles, open the stopcock and the air bubbles will remove


How do you condition a buret?

To condition a buret, first rinse it with distilled water to remove any contaminants. Then, rinse the buret with the solution you will be using by filling it partially, swirling it to coat the inner surfaces, and then draining it completely. This ensures that the inner surfaces are coated with the solution, reducing the risk of dilution from residual water. Finally, fill the buret with the solution to the desired level, ensuring there are no air bubbles in the tip.


How do you properly take a buret reading?

To properly take a buret reading, first ensure that the buret is clean and free of air bubbles. Position the meniscus at eye level to avoid parallax error, and read the value at the bottom of the meniscus. Ensure that you record the reading to the nearest 0.01 mL for accuracy. If necessary, repeat the reading to confirm consistency.


How a buret is filled up?

To fill a buret, close the stopcock at the bottom, pour the solution into the top of the buret, open the stopcock slightly to allow air bubbles to escape, and then close the stopcock once the solution reaches the zero mark on the scale. Adjust the meniscus by gently tapping the buret if needed.


Why need to ensure no air bubbles when acids-base titration?

The buret is a device to preciseely measure volume while being able to deliver a varying amount of stuff. If youare assuming that the volume you have so accurately measured is of, say, hydrochloric acid, and then you end up with an air bubble (not hydrochloric acid) then the precise volume reading on the buret is inaccurate.


How to use a buret properly for accurate measurements?

To use a buret properly for accurate measurements, first rinse the buret with the solution you will be using to remove any impurities. Then, fill the buret with the solution, making sure there are no air bubbles. Record the initial volume reading. Slowly add the solution to the receiving flask while swirling gently. When you reach the desired volume, record the final volume reading. Subtract the initial volume from the final volume to determine the volume of solution dispensed.


How would air bubbles in the tip of a buret of Na OH effect the efficiency number of antacids?

The final reading is then taken including the bubbles. So if the bubbles are 2 mL and your buret reads 12 mL. It seems like there is 12mL added, but the bubble was not taken into account. So you only pipetted 1o mL yet the bubble made it seem like 12.


What happens when you forget to remove the air bubble from the tip of the buret that contains NaOH in a titration?

If you forget to remove the air bubble from the buret tip, it can affect the accuracy of the titration results. The air bubble can displace some of the liquid in the buret, leading to an incorrect volume measurement of the NaOH solution delivered. This can result in errors in the determination of the unknown concentration of the other solution being titrated.


Why is it necessary to remove all the air in IV tubing?

Removing all the air from IV tubing is important to prevent air embolisms, which can block blood vessels and be life-threatening. The air bubbles can also affect the accuracy of medication delivery.


How can I effectively remove air bubbles from painted walls?

To effectively remove air bubbles from painted walls, use a small pin to puncture the bubble, gently press out the air, and then smooth the area with a putty knife or sandpaper.


Why is it poor technique to refill a buret during titration?

Refilling a buret during titration can lead to inaccurate measurements because it may introduce air bubbles or alter the concentration of the liquid being added. It can also affect the precision and reliability of the titration results by causing variations in the volume of liquid being delivered.