answersLogoWhite

0

What do you do when you want to go into a new room and sit down? Do you crawl around the floor until you bump into a chair? No. You stand up an look around the room. You scan the room. When you get close to the chair, you look closer to make sure no one else is sitting in it or to see nothing is resting on the cushion. You use distance vision to find the chair. Then you examine it closely when you are close. Finally you check it to make it will support your weight.

Then you sit down. Then you sit down. You start with the lens with the lowest magnification to locate the specimen. You move the specimen into the center of view. etc.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Natural Sciences

Which adjustment screw must be used when focusing the 40X objective?

The fine adjustment screw is used when focusing the 40X objective. The coarse adjustment screw should only be used with lower magnifications to bring the specimen into rough focus.


Why is it important to focus specimens under the Low Power Objectve before observing it under the High Power Objective?

It allows you to center the specimen, and if it is set up correctly, then when you switch objectives it should still be there and only need fine focusing. It also reduces the chance of crushing the specimen and/or breaking the slide or the lens as the LPO is further away from the slide than the HPO.


When should the high power objective be used?

The high power objective should be used when you need to examine smaller details or structures in a specimen at higher magnification. It provides a higher magnification level compared to the low power objective, allowing you to see finer details.


When beginning to focus a microscope what lens should you use?

You should start by using the lowest power objective lens, usually the 4x or 10x objective, to locate and center the specimen on the slide. Once the specimen is in focus, you can switch to higher magnifications for more detailed viewing.


What objective should be used for initial focusing explain?

The objective for initial focusing should be to clearly define the problem or goal that needs to be addressed. This involves understanding the purpose, scope, and desired outcomes of the project or task at hand. By establishing a clear objective, the team can align their efforts and resources towards achieving a common goal.

Related Questions

When focusing a specimen you should always start with the?

When focusing a specimen, you should always start with the lowest magnification objective lens, typically the scanning objective (4x or 10x). This allows for a broader field of view, making it easier to locate the specimen. Once the specimen is centered and in focus at low magnification, you can then switch to higher magnification lenses for more detailed observation. Always use the coarse focus knob first, followed by the fine focus knob for precision.


When focusing a specimen you should always start with which objective?

You should start focusing with the lowest magnification objective, typically the 4x objective. This allows you to locate and center your specimen before moving to higher magnifications.


When focusing with a microscope do you always focus toward the specimen?

No, when using a microscope, you should focus away from the specimen initially by moving the objective lens upward, then slowly bring it down towards the specimen to avoid damaging the lens or the specimen.


Which adjustment screw must be used when focusing the 40X objective?

The fine adjustment screw is used when focusing the 40X objective. The coarse adjustment screw should only be used with lower magnifications to bring the specimen into rough focus.


Why should you always move the objective lens away from the slide when your focusing the microscope?

Moving the objective lens away from the slide when focusing prevents the lens from accidentally coming into contact with the slide and potentially damaging both the lens and the specimen. It also helps in preventing the lens from scratching the slide, ensuring clear and accurate observations.


When viewing a specimen under the microscope you should always start with what?

When viewing a specimen under the microscope, you should always start with the lowest magnification objective lens. This allows you to locate and focus on the specimen before moving to higher magnifications for a closer look.


When focusing a microscope what do you start with?

When focusing a microscope, you should start with the lowest power objective lens, typically the scanning objective (4x or 10x). This allows you to locate the specimen easily and focus without risking damage to the slide. Once the specimen is centered and in focus, you can switch to higher power objectives for more detailed viewing. Always use the coarse focus knob first, followed by the fine focus knob for precise adjustments.


When viewing a specimen under the microscope you should always start with the?

low power objective lens to locate and focus on the specimen before moving to higher magnifications.


Why should preliminary focusing always be done upwards?

When focusing the microscope downward, you take the chance of damaging the expensive objective lens by crushing the slide trying to get it.


What particular objective should be use when a general view of the specimen is to be used?

When starting a microscopic study,always examine under LPO first.Move the slide and get a good general view of the specimen.


What should you do when viewing a specimen under highpower if you completely lose the focus?

If you completely lose focus while viewing a specimen under high power, you should first move the fine adjustment knob in both directions to try and regain focus. If that doesn't work, switch back to a lower magnification objective lens, refocus the specimen, and then switch back to the high power objective to try focusing again.


When should the course adjustment knob be used?

The course adjustment knob should be used when initially focusing on a specimen under low power magnification, typically with a microscope. It allows for quick and significant changes in the stage height to bring the specimen into the general focus. Once the specimen is in focus, the fine adjustment knob should be used for more precise focusing, especially at higher magnifications. Using the course adjustment knob at higher powers can risk damaging the slide or the objective lens.