Whoa there! You are setting yourself up for an absolute disaster. There is no way to do what you are trying safely OR legally. If your generator is a small one, it probably has only 120V output. Your dryer outlet is 240V. There is no combination of wires that will work properly since you could feed only one or the other hot leg. If you do manage to get it hooked up somehow, you could backfeed your generator voltage on to the dead utility power lines feeding your house. This is quite illegal, and several utility workers have been killed in the past by someone doing exactly what you are trying to do. Also, when the utility power comes back on, it will destroy your generator and possibly cause a fire. You NEED to have a qualified individual install a manual transfer switch and move the desired branch circuits to it. then you will have a place all set to plug the generator into, and the interlock feature prevents you from cross connecting utility and generator power. No offense, but you will hurt someone if you do not get help. IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS. If you do this work yourself, always turn off the power at the breaker box/fuse panel BEFORE you attempt to do any work AND always use a meter or voltage indicator

to insure the circuit is, in fact, de-energized.

User Avatar

Wiki User

16y ago

What else can I help you with?

Continue Learning about Natural Sciences

Can you have a smaller gauge ground?

Having a smaller gauge ground wire may lead to increased electrical resistance and potential overheating. It is important to ensure that the gauge of the ground wire is appropriately sized to handle the electrical load and prevent safety hazards such as electrical fires. It is recommended to consult with a qualified electrician to determine the correct gauge for your specific electrical system.


If your generator has a 4-prong 240V 30A receptacle 8500W peak and your stick welder has a 3-prong 240V plug how do you make this work?

Before you follow any of these instructions, make certain that you check with the documetation that came with the generator, since I can't be certain of what your generator is doing. The following assumes that the generator provides 220 output and is NOT 3 phase. If it's 3 phase, all of the following is wrong and don't do this! In general, 220 circuits have 2 110 "leg's" which are nothing more than a center-tap into the 220 source. It can be a center tap on a transformer or a generator. The center tap is designated with a white wire, and the two "hot" lines are usually designated with either black or red. In the case of your generator, if it is not a 3 phase circuit, the 4th wire is probably green which is the universal indicator for a ground wire. To be safe, it is a good idea to ground the generator using a long, copper grounding rod that has been driven into the ground and using a good sized wire (typically #10 or larger) connect it to the generator at the grounding lug, again, see instructions that came with the generator. To make the welder work with the generator, you can "get by" connecting the white wire to the white of the generator or if you're using a plug connect it to the silver screw. The two black wires or the black and red wires are connected to the two brass colored screws. Whenever a ground wire is provided on a wire it should be connected to grounding screw of the plug. I hope this is enough information. If you have any questions, contact the manufacturer or a local electrician.


Single phase 4 pole Gen alt w 240V 60hz output no neutral. you check from each lead to ground and get 50-70V How do you get a neutral for connecting Gen to a standard breaker box having 240V and 120V?

Neutral is at the jumper that changes it from 120v to 240v. Two stator windings are used in series to make 240v; at that junction is (when wired in Series)your neutral/common/ground. Ground this terminal and use it for your neutral/common. When wired in parallel you have 110v and the jumper is removed and there is no common/neutral and ground is from the frame of the generator.


Why is the ground wire smaller in your 8 2 with ground wire?

The grounding wire is not intended to be a load-carrying conductor in ordinary use, but rather a SAFETY conductor. Grounding wires are often "one size smaller" than the associated load conductors in the same cable.


When do all electrons in an atom have the lowest possible energies?

This is called the "ground state", all electrons occupy the orbitals of lowest energy available to them.

Related Questions

Is allis chalmers ca positive ground?

It Depends. Is is a new style alternator? or old generator? if it was the old style generator on the tractor it will be positive ground. If it was the alternator is is negative ground.


Does common wire act as ground when hooking up 230 volts single phase?

Not always


What does system floating mean in reference to portable generators?

There is no path to ground. IE: You need to ground the generator using a ground rod.


Do I need to ground my generator for safety purposes?

Yes, grounding your generator is important for safety purposes to prevent electrical shocks and fires.


What can happen if a utility-sized electrical generator has an ungrounded neutral?

What you need to define is the statement "utility- sized electrical generator". It depends on what the generators output is used for as to the way it is internally wired. In some configurations there is no neutral to ground as in a Delta configuration.If the generator is configured for a Wye output and the neutral centre tap is not grounded there will be a floating voltage between the generator and the utility system ground. It is for this reason that the generator's neutral point is grounded to bring the floating voltage down to zero volts to ground.


Which is smaller finely ground pepper or salt?

Finely ground pepper.


Could my battery not charge from a bad ground?

Yes, a poor or open ground would prevent an alternator or generator from being charged.


Working of function generator?

After powering on the function generator, the output signal needs to be configured to the desired shape. Typically, this means connecting the signal and ground leads to an oscilloscope to check the controls. Adjust the function generator until the output signal is correct, then attach the signal and ground leads from the function generator to the input and ground of the device under test. For some applications, the negative lead of the function generator should attach to a negative input of the device, but usually attaching to ground is sufficient


When hooking up a snap-on scanner to 1994 Toyota Camry you get 'no communication with ECM' what does this mean?

Check power and ground betwen the ecu an the computer link connrctor


Where should the ground wire be connected if there is no ground available?

If there is no ground available, the ground wire should be connected to a metal water pipe or a metal rod driven into the ground to provide a safe path for electrical currents.


Why do smaller wheel sizes keep the skateboard closer to the ground?

Well, think about it. If you have a small wheel, the smaller the diameter, height and width. Therefore closer to the ground.


What should be done with the ground wire if there is no ground available?

If there is no ground available, the ground wire should be connected to a metal water pipe or a grounding rod to provide a safe path for electrical currents.