The refrigerant pressure inside an R-410A unit at room temperature (72 degrees F) and not operating will typically be around 118-120 psi for the low side and 405-435 psi for the high side. These values may vary slightly depending on factors like elevation and specific system conditions.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Continue Learning about Physics

What is the internal pressure of a cylinder with one ounce of liquid R-410A refrigerant which has been sitting in a 100 degree Fahrenheit truck is?

The internal pressure of the cylinder would depend on the temperature of the refrigerant. At 100 degrees Fahrenheit, the pressure of R-410A refrigerant would be approximately 212 psi at equilibrium.


What internal pressure of a cylinder with one ounce of liquid R-410A refrigerant which has been sitting in a 100 degree Fahrenheit truck is?

The internal pressure of a cylinder containing R-410A refrigerant with one ounce of liquid will depend on various factors such as the temperature-pressure relationship for R-410A and any external conditions affecting the temperature of the refrigerant. However, at 100 degrees Fahrenheit, the pressure of R-410A is approximately 228 psi.


When outside ambient air temperature is 90 degree the temperature of the condening refrigerant in a standard efficiency unit should be approximately?

The condensing temperature of the refrigerant in a standard efficiency unit should be around 30-40 degrees Fahrenheit higher than the outdoor ambient temperature. Therefore, when the outside temperature is 90 degrees, the condensing temperature of the refrigerant would be around 120-130 degrees Fahrenheit.


What is the temperature limit for operating the equipment safely?

The temperature limit for operating the equipment safely is 40 degrees Celsius.


If an air conditioner evaporator coils is setup so the refrigerant is vaporized at forty five degrees Fahrenheit What is the pressure in the evaporator coil?

The pressure in the evaporator coil would depend on the type of refrigerant being used. Different refrigerants have varying pressure-temperature relationships. Without knowing the specific refrigerant being used, it is not possible to provide an accurate pressure value.

Related Questions

What is the boiling temperature of refrigerant 404A?

The boiling temperature of refrigerant R-404A at atmospheric pressure is approximately -46.5 degrees Celsius (-51.7 degrees Fahrenheit). However, this temperature can vary slightly depending on the specific pressure conditions in the system. R-404A is commonly used in refrigeration applications, particularly for low and medium-temperature systems.


What is the internal pressure of a cylinder with one ounce of liquid R-410A refrigerant which has been sitting in a 100 degree Fahrenheit truck is?

The internal pressure of the cylinder would depend on the temperature of the refrigerant. At 100 degrees Fahrenheit, the pressure of R-410A refrigerant would be approximately 212 psi at equilibrium.


What internal pressure of a cylinder with one ounce of liquid R-410A refrigerant which has been sitting in a 100 degree Fahrenheit truck is?

The internal pressure of a cylinder containing R-410A refrigerant with one ounce of liquid will depend on various factors such as the temperature-pressure relationship for R-410A and any external conditions affecting the temperature of the refrigerant. However, at 100 degrees Fahrenheit, the pressure of R-410A is approximately 228 psi.


When outside ambient air temperature is 90 degree the temperature of the condening refrigerant in a standard efficiency unit should be approximately?

The condensing temperature of the refrigerant in a standard efficiency unit should be around 30-40 degrees Fahrenheit higher than the outdoor ambient temperature. Therefore, when the outside temperature is 90 degrees, the condensing temperature of the refrigerant would be around 120-130 degrees Fahrenheit.


What is the low side and high side pressure for r410a?

Technicians with R-22 experience will need to become familiar with working with high and low side pressures that are much higher when using R-410A. A typical R-22 system operating normally with a head pressure of 260 psig at a 120-degree condensing temperature and a low side pressure of 76 psig at a 45-degree evaporator saturation temperature will find the equivalent pressures in a R-410A system to be much higher.A normally operating R-410A system with the same condensing temperature of 120 degrees and a 45 degree evaporator saturation temperature will have a high side pressure of 418 psig and a low side pressure of 130 psig.Although refrigerant 410A is a near-azeotrope and has a slight temperature glide, there is no need to correct for refrigerant dew point and bubble point differences. Superheat and sub cooling calculations can be calculated the same way we have always done with R-22 refrigerant. The only difference will be the higher pressure-temperature relationship when reading the temperature-pressure chart. The temperature glide for R-410A is only .3 degrees Fahrenheit and can be ignored and fractionation is not a concern.


What refrigerant has the lowest boiling temperatures at atmospheric pressure?

R-502 has thelowestboiling temperature atatmosphericpressure. It can be boiled as low as -50 deg F before the boiling pressure goes into a vacuum.


What is the normal operating temperature of an engine?

the normal operating temperature for cars is around 190 degrees.


What is the operating temperature of a 1997 Chevrolet Cavalier 2.2L?

The 1997 Chevrolet Cavalier 2.2 liter engine operating temperature is 180 degrees. Aftermarket thermostats can allow the operating temperature to rise to 195 degrees.


How do you charge 410a by subcooling?

To charge R-410A by subcooling, first, ensure the system is operating at stable conditions. Measure the liquid line temperature and pressure, then refer to the manufacturer's charge chart to find the corresponding saturation temperature for the pressure. Calculate the subcooling by subtracting the saturation temperature from the measured liquid line temperature. Add refrigerant until the desired subcooling level, typically between 10 to 15 degrees Fahrenheit, is achieved, ensuring optimal system efficiency.


What is the temperature limit for operating the equipment safely?

The temperature limit for operating the equipment safely is 40 degrees Celsius.


What is teperature drop across evaporator?

The temperature drop across an evaporator refers to the difference in temperature between the refrigerant entering the evaporator and the refrigerant leaving it. This drop occurs as the refrigerant absorbs heat from the surrounding environment, causing it to evaporate and change from a liquid to a gas. The magnitude of this temperature drop is crucial for the efficiency of refrigeration systems, as it influences the heat transfer process and overall system performance. Typically, this drop can range from a few degrees to several tens of degrees Fahrenheit or Celsius, depending on the system design and operating conditions.