image magnification,image distortion,image un sharpness
The process involves positioning the patient on the radiographic table, adjusting the x-ray equipment, and shielding the patient when necessary. The radiologic technologist then takes the x-ray image and ensures it is of diagnostic quality before saving it for review by the radiologist or physician.
The study of unacceptable radiographs is called radiographic reject analysis. It involves evaluating radiographs that do not meet quality standards to identify the reasons for rejection and improve image quality.
No, increased source-to-image receptor distance (SID) does not directly affect film density. Film density is primarily influenced by factors such as exposure technique (mAs and kVp), film processing, and the characteristics of the tissue being imaged. However, changes in SID can indirectly impact the overall image quality and detail captured on the film.
As film screen speed increases, radiographic density decreases. Faster film screens require less exposure to produce the same density as slower film screens. This relationship is important in balancing exposure settings to achieve optimal image quality.
The main difference between keV and kVp in radiography is that keV refers to the energy of the X-ray photons used to create the image, while kVp refers to the peak voltage applied to the X-ray tube. Adjusting keV affects image contrast and sharpness, while adjusting kVp affects overall image brightness and penetration. Both factors play a crucial role in determining the quality of the radiographic image.
He is responsible for the quality paramiters and other things like opening of the call, reason of the call body of the call that all things which are related to quality.
The process involves positioning the patient on the radiographic table, adjusting the x-ray equipment, and shielding the patient when necessary. The radiologic technologist then takes the x-ray image and ensures it is of diagnostic quality before saving it for review by the radiologist or physician.
The study of unacceptable radiographs is called radiographic reject analysis. It involves evaluating radiographs that do not meet quality standards to identify the reasons for rejection and improve image quality.
Reticulation of radiographic film refers to a pattern of fine lines or a mottled appearance that can occur on the film due to improper processing. This phenomenon is often caused by extreme temperature changes during the developing process, particularly when the film is rapidly cooled or heated. It can compromise the quality of the radiographic image, making it difficult to interpret. Proper temperature control and processing techniques are essential to avoid reticulation.
No, increased source-to-image receptor distance (SID) does not directly affect film density. Film density is primarily influenced by factors such as exposure technique (mAs and kVp), film processing, and the characteristics of the tissue being imaged. However, changes in SID can indirectly impact the overall image quality and detail captured on the film.
factors that affect dimension of quality
VALUE
value
· Operating x-rays equipments and processing exposed images.· Positioning patients for diagnostic examinations· Calculating proper exposure factors to achieve optimum radiographic image quality with minimum exposure to the patients.· Assessing the diagnostic quality of the radiograph.Assisting the radiologist during specific procedures, assisting patients while in your care
Density, contrast, distortion, and recorded detail. Radiography Essentials for Limited Practice: Bruce W. Long, Eugene D. Frank, Ruth Ann Ehrlich