answersLogoWhite

0

The minimum negative surge pressure that can occur in a pipeline is typically determined by factors such as the operating conditions, pipe materials, and design parameters. It is important to properly analyze the system to prevent excessive negative pressures that may lead to pipeline damage or other issues.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Related Questions

What happens if the pressure cap on the surge tank is left loose defective or will not hold pressure?

If the pressure cap on the surge tank is left loose, defective or will not hold pressure.


How do you find centrifugal compressor is in surge?

Normaly, every centrifugal type comprssors provided with an antisurge valve or surge control valve. when compressor handelled with surge, the proveded surge control valve will become open automatically and the cycle will repeated till the comprssor is in surge.


What is surge limit in cetrifugal compressor?

Surge Limit is the Minimum Flow Point ( in the compressor characteristic curve ) below which the compressor operation become instable. If the flow-rate is reduced, the pressure developed by the compressor decreases. Then, the pressure in the discharge line becomes greater , and the gas flow back into the compressor. As soon as the pressure in the discharge line drops to below that developed by the compressor, the gas again flows in the discharge line. Then, the cycle repeats. The oscillating pressure and flow rate will cause audible vibrations and shocks, and could damage the compressor blades, seals, and other components. Therefore, the compressor requires an antisurge control system to limit the flow rate at a minimum point, safely away from the surge limit.


What is minimum recommended surge protection for an iMac?

First of all look for a surge protector with a UL (Underwriters Laboratory) rating. If it does not have one you can rest assured is junk. But just because it has one does not mean is an excellent surge protector. Be sure that the product is listed as a transient voltage surge suppressor. Get a surge protector with a minimum of 1200 joules. Normally the more money you spend the better protection you get but, that is not necessarily always the case.


What is the maximum negative pressure can be reached in a system?

The maximum negative pressure in isolated system is negative ATM. ATM is the pressure created by air molecules and it is 1.01325*10^5 Pa. So a negative pressure of 1 ATM means absolute vacuum.


Can you make a sentence with the word surge?

The team's success had led to a surge in the sale of game tickets. Financial troubles and family conflicts made his blood pressure surge.


What causes a hurricane's storm surge other than a combination of high winds?

Low pressure also contributes to the storm surge.


Can reciprocating compressor surge?

Compressor surge only occur in centrifugal compressors. reciprocating compressor don't as they increase pressure by volume reduction, unlike centrifugal compressors where they increase pressure by converting kinetic energy to potential energy (pressure).


Is a minimum a positive or negative?

It depends on whether or not what you are measuring is good or bad. Most people would say that minimum pain is positive or that minimum happiness is negative.


How do you measure negative pressure?

Negative pressure is typically measured using a device called a manometer, which can accurately detect and quantify the pressure difference between the reference point and the negative pressure source. The manometer displays the pressure reading by using a fluid column that moves based on the pressure applied to it, providing a visual indication of the negative pressure level.


When was Negative pressure ventilator created?

Negative pressure ventilator was created in 1928.


The minimum safety-relief pressure for a R-410A cylinder is .?

minimum pressure is 525 psig for R-410A