answersLogoWhite

0

run. no ITs the start

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Physics

What is the advantage and disadvantage of wave winding?

Advantage: Wave winding provides a higher voltage output compared to lap winding with the same number of turns in the armature. This winding type also allows for better cooling due to the interleaved nature of the winding. Disadvantage: Wave winding is more complex to construct and repair compared to lap winding. It also requires more insulation material between the turns, which can increase the overall size of the winding.


How do you start a clock that has stopped?

To start a clock that has stopped, first check if it needs winding or a new battery. If it requires winding, gently turn the key or knob in the direction indicated for winding until the clock starts ticking again. If it needs a new battery, replace it according to the manufacturer's instructions.


What is the abbreviation for winding?

The abbreviation for winding is "wnd" or "wdg".


What form of energy does get used when winding the mainspring of a clock?

When winding the mainspring of a clock, mechanical energy is used. This energy is transferred to the mainspring through the winding key or crown, which tightens the spring inside the clock mechanism.


How could you modify a solenoid to produce a stronger magnetic field?

Hi, By using two windings instead of one. One is a low resistance winding that provide the strong pulling force and a second one (the hold winding) to supply the holding force. When first turned on, both winding provide the strong pulling force needed to actuate the solenoid. As the plunger reaches its final on position, the strong winding is switched off by a built in switch actuated by the plunger. This winding arrangement is used extensively in car starters. René

Related Questions

Which winding has the higher resistance start or run in single phase motors?

start winding is thicker with less number of winding whereas run winding is less thicker than start winding but with more number of winding. As we know inductance depends upon numbers of turns of winding so run winding will have more inductance.


How do you identify start and run windings of a motor?

The run winding of a single phase capacitor start motor has a lower resistance than the start winding.


How do you wire a 220 volt motor with 6 wires?

you have to ohm out the wires the start windings will have a higher resistance and the run windings will have a lower resistance if you have 6 wires then you may have a dual motor 1start winding and 2 run windings each having 2 wires the start windings and the run windings are all hooked up in parallel with the start capacitor hooked up in series with the start winding


The function of a start winding in a split-phase motor is to?

a start winding on a motor is used to add torque to start a motor, and more importantly to establish the direction that the motor will turn. to reverse a motor normally means to reverse the start winding. the run winding will work the same in either direction, the start winding determines the direction.


Can a single phase 220 motor run backwards?

Changing motor rotationA split phase induction motor has two sets of coils and a centrifugal start switch. The start winding is in series with the start switch. The start winding provides a rotating magnetic field in one direction enabling the motor to start. The motor can be reversed by reversing the connections of either the start winding or the run winding but not both.


At what approximate percentage of the normal run speed is the start winding disconnected from the circuit?

The centrifugal switch on a motor's start winding should open at 75 to 80 percent of the motors run speed RPM.


What causes an AC 220 motor to spin counter-clockwise?

The inter changing of either the start winding or the run winding.


What are the three main part of single-phase motors?

The main parts are the stator and the rotor.After that depends on the type of single phase motor. This includes capacitors (start and/or run),centrifugal switch (stationary and rotary) Also there are usually two windings,a start and a run winding. In its most basic form the start and run winding are connected together at one end of the windings (common) the other end of the run winding connected via a centrifugal switch and/or run capacitor to the other end of the start winding. Power is supplies to the run winding terminals. The start capacitor is fitted in series with the centrifugal switch, allowing it to be disconnected once rotation speed is reached.


How does power pass through compressor to inside motor?

. Through a terminal box with three motor terminals one for the run winding and one for the start winding and one for the common line to the run and start windings


How do you reverse a single phase 220volt motor?

A split phase induction motor has two sets of coils and a centrifugal start switch. The start winding is in series with the start switch. The start winding provides a rotating magnetic field in one direction enabling the motor to start. The motor can be reversed by reversing the connections of either the start winding or the run winding but not both.


HOW TO REVERSE DIRECTION ON A single phase motor?

A single phase induction motor has two sets of coils and a centrifugal start switch. The start winding is in series with the start switch. The start winding provides a rotating magnetic field in one direction enabling the motor to start. The motor can be reversed by reversing the connections of either the start winding or the run winding but not both.


Is the resistance in the start winding greater or less than the resistance in the run winding?

The resistance in the start winding is greater because it is longer and thinner and has the greatest resistance to current flow