In a AC contactor, a shaded ring is essential to prevent it from buzzing twice a cycle. Ac contactor takes a input of alternating voltage resulting an alternating current and flux through its windings. So The contactor buzzes each time the magnitude of alternating magnetic field reaches zero. The shaded rings are provided at some part of the core. When the alternating flux cuts them the produce another alternating magnetic field which is out of phase from the main magnetic field. So the resultant magnetic field no more zero at the contacts and which prevents the contact from buzzing.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Physics

What is an alternative to carbon brushes in an ac motor?

An alternative to carbon brushes in an AC motor is using a brushless motor. Brushless motors have permanent magnets and electronic drive systems to operate, eliminating the need for brushes or commutators. This design results in less maintenance, higher efficiency, and longer lifespan compared to motors with carbon brushes.


How do you wire an AC electromagnet?

To wire an AC electromagnet, you would typically connect one end of the coil to the live terminal of the AC power source and the other end to the neutral terminal. It's important to use appropriate wire size and insulation to handle the current and voltage of the AC supply. Additionally, you may need to use a relay or switch to control the circuit.


Why is condensation forming on your ac ceiling vents?

Condensation forms on AC ceiling vents when warm air from the room comes into contact with the cold surface of the vent. This temperature difference causes the moisture in the air to condense and accumulate on the vent, similar to how dew forms on grass in the morning. It's a sign that the AC system may need inspection or maintenance to ensure proper operation.


How many batteries required to run 2 ton ac through ups?

No way to give you a simple answer- will depend on the storage capacity of the batteries, and the efficency of the inverter in the UPS unit, and the efficency of the AC unit. That is a 24,000 BTU air conditioner, with a large current draw- typically 3200-3500 watts. It will also depend on how LONG you will want to run the AC system on battery- it is not for an indefinite time.


What voltage is the Thailand national grid on?

220v ac UK and Europeans will need an adapter, but otherwise ok. US will need a converter.

Related Questions

How does a shading coil in a contactor actually work?

A shading coil in a contactor is used to hold the AC contactor's pole faces closed during the transition of the voltage through the zero voltage phase of an electrical cycle.For an excellent description see related links below.


Can you use an AC contactor in the place of DC contactor?

No, you definitely cannot.


Why is my AC contactor buzzing and how can I fix it?

Your AC contactor may be buzzing due to a loose connection or a faulty contactor. To fix it, you can try tightening any loose connections or replacing the contactor if it is damaged. It is recommended to seek help from a professional HVAC technician for a proper diagnosis and repair.


What is contactor on ac unit?

A contactor in an AC unit is an electromechanical switch that controls the flow of electricity to the compressor and other components. It allows the system to turn on and off, enabling efficient operation of the air conditioning system. When the thermostat signals the need for cooling, the contactor closes, allowing power to flow to the compressor and condenser fan. Conversely, when cooling is no longer needed, the contactor opens, cutting off power to those components.


What is the difference between an definite purpose contactor and a lighting sontactor?

A definite purpose contactor is designed (and rated) for a specific load. So a lighting contactor is one example of a definite purpose contactor. A motor starter contactor is another example. So, a lighting contactor is a definite purpose contactor, but a definite purpose contactor is not necessarily a lighting contactor (it might be a motor starter, for instance).


What are the common signs of a bad AC contactor and how can it be diagnosed and replaced?

Common signs of a bad AC contactor include the air conditioner not turning on or off properly, frequent cycling, or a humming noise. To diagnose a bad contactor, visually inspect it for signs of burning or wear, and use a multimeter to test for continuity. If the contactor is faulty, it can be replaced by disconnecting power, removing the old contactor, installing a new one, and reconnecting the wires.


State two advantages of a triac as compared to an SCR?

triac act as a ac contactor


How many main - line contactor assemblies are used in an across the line AC reversing motor?

2


What is the typical indicator that a shading coil is broken?

Loud buzzing noice in an ac controler


What is the function of the AC compressor contactor in an air conditioning system?

The AC compressor contactor in an air conditioning system is responsible for controlling the flow of electricity to the compressor. It acts as a switch that allows the compressor to turn on and off based on the thermostat's signals, helping to regulate the temperature in the space being cooled.


What is ac1 and ac3 contactor?

AC-1This applies to all AC devices (Resistive loads) with a power factor of at least power factor of 0.95 AC-3This applies to AC Inductive loads. Like squirrel cage motors.


What could be wrong with your home AC central air if the thermostat clicks on and fan but AC unit won't start and new fuses and switching the breaker on and off didn't help?

It could be off on a low pressure switch. You need to check if you have 24 volts to the outdoor unit at the contactor coil. If the contactor is not working the outdoor unit will get no high voltage to the compressor or fan. It could also be that the capacitor for the fan and compressor is blown.