Of course If the flue is sized properly

User Avatar

Wiki User

14y ago

What else can I help you with?

Related Questions

Can 250 CFH gas meter supply a house with a gas furnace and a 200000 BTU water heater?

If your furnace is less then 50000btus then yes.


What is the typical flue gas temperature of a category 3 furnace?

120


What is the purpose of the vent on a gas furnace?

The purpose of the vent on the furnace is to ventilate flue gases out side of the house.


What the purpose of the vent on a gas furnace?

The purpose of the vent on the furnace is to ventilate flue gases out side of the house.


What is the purpose of a vent on a gas furnace?

The purpose of the vent on the furnace is to ventilate flue gases out side of the house.


Can you use the same vent for gas water heater as for gas furnace?

No, you cannot use the same vent for a gas water heater and a gas furnace. Each appliance typically requires its own dedicated venting system to ensure proper exhaust of flue gases and to prevent the risk of backdrafting, which can lead to carbon monoxide buildup. It's important to follow local building codes and manufacturer recommendations for venting to ensure safety and compliance. Always consult a qualified professional if you're unsure.


How do you seal gas flue from furnace?

To seal a gas flue from a furnace, first ensure the flue is properly disconnected from the furnace. Use high-temperature silicone sealant or a metal flue cap to cover the opening, ensuring it is airtight to prevent gas leaks. Additionally, inspect the area for any cracks or gaps and seal them with appropriate materials, such as metal tape or a chimney cap, to ensure proper sealing and safety. Always follow local building codes and regulations for gas appliances.


What flue gas is measured to determine the efficiency of a gas furnace?

The concentration of carbon dioxide (CO2) in the flue gas is typically measured to determine the efficiency of a gas furnace. By analyzing the presence of this gas, technicians can evaluate how effectively fuel is being burned and whether any adjustments are needed to optimize efficiency.


What should be the range of temperature of flue gases at outlet of air pre-heater?

The typical flue gas temp at the inlet to the air heater is about 650-750 DegF range.


Services?

Gas Water Heater gas water heater Gas Water Heater Repair Gas Water Heater Leaking Gas Water Heater Installation Gas Hot Water Heater {40,50} Gallon Gas Water Heater


Is a direct vent water heater as good as a standard vent water heater?

a direct vent water heater is more fuel efficient (cost's less to operate). aside from that there isn't much difference, aside from not needing a double wall flue through the roof on a standard gas water heater.


Can a gas fireplace and a furnace share a chimney?

If both fireplace and furnace are BOTH gas, if the flue has the correct size, AND if your building code permits, yes. If furnace and fireplace are different fuels, no. Check with your local building inspection department.