Yes, galvanised pipes may certainly be used. Making sure that the threaded joints are well sealed, however galvanised piping can be tricky and sometimes difficult to install. Copper pipe is so widely used and preferred because of the soldered joints, you are guaranteed a leak proof joint and much easier to install. Black iron pipe is more commonly used than galvanized. The galvanizing reacts with the gas and can flake off.

I have seen entire housed done in galvanized with no problem, but have come across areas of pipe in others that were completely clogged with the galvanizing flakes.

User Avatar

Wiki User

13y ago

What else can I help you with?

Related Questions

Can you use brass and galvanized pipe for a gas line?

No.


Can schedule 40 galvanized pipe be used for gas line under house?

Use only black pipe


Is it safe to use galvanized pipe for gas?

No, it is not safe to use galvanized pipe for gas because the zinc coating on the pipe can react with the gas and cause corrosion, leading to potential leaks and safety hazards. It is recommended to use black steel pipe or other materials specifically designed for gas applications.


Can galvanized pipe be used for natural gas?

You should use black pipe -- Galv. pipe will flake off inside of pipe


Can you use galvanized connections on gas iron pipe?

Most codes do not allow Galvanized piping/fittings on gas piping. I have used galvanized pipe/fittings on exterior gas piping before in the state of Michigan but other states do not allows this. Check with your local code authorities.


What applications that use black iron pipe rather than galvanized iron pipe?

Black iron pipe is used for gas installations but ONLY if the piping is indoors. Outdoor gas piping is usually done in galvanized pipe. Steam is also piped with black pipe, fire sprinkler and standpipe systems also use black pipe.


Is it all right to use galvanized pipe with black iron pipe?

What is the application as many times such as natural gas it is permissible as gas lines exposed to the elements have to be protected painted / insulated or galvanized piping vanized piping


Should galvanized gas pipe lines be used in stead of black steel pipe for under a raised house on pilings you have one plumber saying to use galvanized and the other black pipe?

Depends on local codes I use Galvanized piping and fitting when I know the piping is going to be exposed to moisture (dampness) or the elements


Can you put galvanized pipe underground?

ya the galvanized pipecan be use in undergrounds,,, because it is an iron pipe


Can you use pvc pipe for gas line?

Absolutely Not!


What type of fitting do you use to connect PVC pipe to unthreaded galvanized pipe?

You can't. There is no fitting to do this. Galvanized has to be threaded.


Can you use black PVC or Quest pipe for natural gas?

NO..copper,black iron, galvanized for gas pipe.never use plasticp solvents or glue.gas does not react well with other chemicals.