Yes i drain line has got to be vented. A sewer line creates gases which has to be vented otherwise two things happen. Either, you get terrible smells around your property or your sewer lines can explode due to trapped sewer gases, this is costly and can be a painful smelly experience.

User Avatar

Wiki User

16y ago

What else can I help you with?

Related Questions

How can I vent a shower drain properly with the help of a diagram?

To properly vent a shower drain, you can install a vent pipe that connects to the drain line and extends through the roof of your house. This vent pipe allows air to enter the drain system, preventing airlock and ensuring proper drainage. Here is a diagram to help you understand the setup: diagram of a vent pipe connected to a shower drain line and extending through the roof


How can you clean out clogged drain line from roof vent to kitchen sink when you cannot open the cleanout?

Take your snake on the roof and clean the drain from the vent.


What is vent piping?

Vent piping is a pipe that runs outside and is connected to the drain line of your home. this helps the water in the drain to move to your septic/sewer.


How to Drain air out of water pipe?

Install an automatic air vent on the line


Can you add a shower drain to a tub drain or does it need its own waste and vent line?

It's best to have a separate waste and vent line for a shower drain. Introducing a shower drain to a tub drain without a separate line can lead to drainage issues and potentially cause backups or slow draining in the system. It's important for each fixture to have its own dedicated waste and vent line to ensure proper drainage and venting.


Do you install a vent line below the p trap?

The drain pipe should have a vent that goes up where the sink drain goes into it. That is where it vents. Sinks drain because there is nothing causing a vacuum when the water leaves the sink.


Can a sanitary tee be used horizontal as a vent?

as long as it is not installed on a drain line. If it is used strictly on the vent system then yes it can be used horizonally.


Why is there water coming out of the vent on the side of the sink when your dishwasher drains?

Partially clogged drain line.


Does the Ontario plumbing code allow a U loop in a vent line for a basement bathroom to get around a heating duct?

No plumbing code allows a loop in a vent line. They must be pitched just like a drain line as there are many conditions where water can be in a vent line, such as rain through a roof vent and condensation. If the "u" were to fill with water it would no longer function as a vent.


Why does your bath gurgleand tiolet rise when it is flushed?

Drain line starting to clog or vent not working properly.


When you have a shower toilet gurgles water backs up what do you do?

Your drain line is plugged somewhere after your shower and toilet line are connected. The reason for the gurgle in your toilet is because air is trapped in the drain and your toilet is the closest place for air to flow to. If you had a vent on your toilet trap arm then it would gurgle in the vent rather in your toilet but your drain is still plugged and needs to be snaked out and maybe your drain line needs to be examined for right grade or broken.


How do you stop a new gurgling in your kitchen sink after installing a new sewage sump pump?

Make sure the drain line and the vent are cleared. Noises like that are usually caused by either restricted flow or a plugged drain vent.