Im not familiar with the term cheater vent. Perhaps you are referring to an Automatic Air Vent or Air Admittance Valve? They are installed per the manufacturers reccomendations. Some municipalitys around the US recognize these, but do not allow them. They work on the basis that once installed if there is negative pressure in the waste arm from the act of water being flushed through the p-trap and down the waste line they allow air to be entered into the system to protect the trap seal. Masterx3

User Avatar

Wiki User

16y ago

What else can I help you with?

Related Questions

What is the purpose of a sewage vent pipe in a plumbing system?

The purpose of a sewage vent pipe in a plumbing system is to release gases and odors from the sewage system to the outside, preventing pressure buildup and ensuring proper drainage flow.


How do you stop a new gurgling in your kitchen sink after installing a new sewage sump pump?

Make sure the drain line and the vent are cleared. Noises like that are usually caused by either restricted flow or a plugged drain vent.


What is an air admittance vent?

An air admittance vent is a mechanical sewer vent which allows air to enter into the sewage system but does not allow exhaust of sewer gases.


What could be causing the sewage smell in my bathroom?

The sewage smell in your bathroom could be caused by a blockage in the plumbing system, a dried-out P-trap, a malfunctioning vent pipe, or a problem with the sewer line. It is important to address this issue promptly to prevent further problems.


Can you vent air into a sewer vent pipe?

No. You vent air from a sewer line.


How can i get rid of the nasty sewage smell that is coming up the shower drain?

see that vent is downstream from trap


What is wrong if there is a smell of sewage coming back up your bathroom pipes?

Your drain waste vent is plugged or leaking somewhere. The drain waste vent is a pipe that carries sewage gas out of your home, exiting usually the roof but sometimes the side of the house. Get it fixed asap, this is not good for you.


Can you install a shower drain and separate bathtub drain off one trap in a concrete floor?

ofcourse you can - just add a cheater vent to allow you more air than the main stack would supply to supplement any suctioning of your P-trap which would cause noxious sewage fumes up the drain not in use.peace outGREAT idea "cheater venting" to make sure the building gets a violation and the occupants are exposed to carcegenic fumes and the inspector when this is found takes away the C of O .Ever wonder why it maybe called "cheater"


What is the purpose of the sewer vent pipe in the yard and how does it function within the overall sewage system?

The sewer vent pipe in the yard helps to release gases and odors from the sewage system. It functions by allowing air to enter the pipes, which helps prevent blockages and maintain proper flow of waste. This helps to keep the sewage system working efficiently and reduces the risk of backups or damage to the pipes.


Can you wet vent a sewage ejector pump or is it better to run vent to outside through side of house provided there's no windows or air intakes near vent location you will install vent cap at exit wall?

No you cannot wet vent an ejector pump and no you cannot vent through a side wall. It must go through the roof.


Does the Ontario plumbing code allow a U loop in a vent line for a basement bathroom to get around a heating duct?

No plumbing code allows a loop in a vent line. They must be pitched just like a drain line as there are many conditions where water can be in a vent line, such as rain through a roof vent and condensation. If the "u" were to fill with water it would no longer function as a vent.


What size is the gas line?

gas and vent line dts 2004