answersLogoWhite

0

An audible sound or a visual device that operates when a fire alarm is activated. Audio devices may include speech systems, sirens, sounders bells etc. While visual devices may be strobes.

User Avatar

Hudson Parisian

Lvl 10
3y ago

What else can I help you with?

Related Questions

What is a fire alarm panel?

Mimic panel in fire alarm system 'mimics' or mirrors the signal of the Main Fire Control Panel.


How a mimic panel works in fire alarm system?

Mimic panel in fire alarm system 'mimics' or mirrors the signal of the Main Fire Control Panel.


What is the signal for a fire on board a ship?

The signal for a fire on boards is a long blast on the ship's whistle along with sounding of the vessel's general alarm.


Why to use pnp transistor in fire alarm circuit?

You can use a PNP or an NPN transistor in a fire alarm circuit. Both will work. It all depends on how you want to energize the alarm, and with what polarity of signal.


Why does a fire alarm sound different than a tardy bell?

To meet fire code requirements, an emergency alarm must be a "distinctive" signal, so it will not be confused for something ordinary.


Why fire alarm important?

Fire alarms are good because it gives you an early signal which could save you and your familys life.


How does fire alarm using ic 555 works?

A fire alarm using the IC 555 operates in a monostable mode, where it detects changes in temperature or smoke. When a sensor (like a thermistor or smoke detector) triggers the circuit, it sends a signal to the 555 timer, causing it to output a high signal. This output can activate a buzzer or alarm, alerting users to potential fire. Additionally, the timing components can be adjusted to set the delay before the alarm sounds, allowing for false alarm mitigation.


Why 0.04 micro farad capacitor is used in a thermistor based fire alarm?

A 0.04 microfarad capacitor in a thermistor-based fire alarm is typically used for filtering and stabilizing the voltage signal from the thermistor. This capacitor helps smooth out any noise or fluctuations in the signal due to temperature changes, ensuring more accurate detection of temperature rises indicative of a fire. Additionally, it can aid in timing circuits and improve the response time of the alarm system by integrating the signal over time.


Role of timer in fire alarm?

Depends. Most fire alarm panels have delay overrides in them so maybe when the fire alarm initially gets triggered, it waits a few minutes/seconds while the person investigates the cause of the alarm. Once the time is up, the alarm sounders/bells automatically start activating. In some other cases, you could have a class change feature in which the panel is programmed to sound the fire alarms at a certain time in the day- for example, class change in a school, the fire alarms produce a signal from the panel to signal class change.


What is a non-coded type fire alarm signal?

A non-coded type fire alarm signal is a straightforward alarm system that emits a continuous sound or visual alert without any specific pattern or code. This type of signal is designed to quickly notify occupants of a fire or emergency situation without the complexity of coded signals, which may indicate different types of alerts or specific locations. Non-coded signals are often used in simpler systems, ensuring immediate recognition and response.


Which alarm can protect people from fire?

Fire Alarm


What the function of water flow switch in fire sprinkler system?

The function of a water flow switch is to detect water flow in the sprinkler system, usually during a fire event, to signal a local electrical fire alarm, or fire alarm panel to activate the alarm devices in the building,and send an alarm signal to a central station or alarm company to alert the fire department.