WHEATSTONE BRIDGE : A wheatstone bridge is used to measure an unknown electrical resistance by balancing two legs of a bridge circuit, one leg of which includes the unknown compound.Its operation is similar to the original potentiometer.
METER BRIDGE : A uniform resistance wire 1 meter in length, mounted above a scale marked in millimeters, with terminals added to make the device usable as either part of a wheatstone bridge or of a potentiometer.
An Ohm Meter.
DC Bridge... We use DC supply, Detector is also a DC current detector and we use only resistive components no need for wegner's earthing device balancing time is comparatively less.. where as in AC bridges opposite of above. i.e. AC supply, AC current detector resisitive+ reactive componants need for wagner's earthing device and balancing time is high as we use AC supply..
A meter bridge is used to measure an unknown electrical resistance by comparing it with a known resistance. It works on the principle of Wheatstone bridge. By balancing the bridge circuit, the value of the unknown resistance can be calculated accurately.
A Carey-foster's bridge is a modified version of the meter bridge (wheatstone bridge or potentiometer). It can be used to find out the average resistance per unit length of the meter bridge wire and hence find out the unknown resistance. It is more accurate and more sensitive than a meter bridge.
There is no great difference between between the two in principlebut,In a Carey foster's bridge there is no end resistance whereas in the case of a metre bridge end resistance afffects our readings.Hence Carey foster bridge is more accurate than metre bridge .Carey foster bridge can also measure low resistance and high resistance but a metre bridge cannot do so.
The wheatstone bridge is an instrument used to measure electrical resistance by means of balancing a bridge circuit. The bridge circuit contains two legs, one of which contains the unknown resistance. Variations in wheatstone bridge can be employed to measure inductance, capacitance, and impedance also.
The end correction of a meter bridge can be measured by comparing the balance point of a known standard wire to the balance point of an unknown wire on the meter bridge. The difference in lengths between the two balance points is equal to the end correction.
"in" and "out" are the direction of the pressure.
None.
A wheatsone bridge is an electrical circuit made from 4 resistors, 3 of a precisely known value and a 4th of unknown value which we want to measure. There is also a volt meter. See Wikipedia link for circuit diagram and more info.
Hello
LCR meter is a device. And electrochemical impedance spectroscopy is a method. So the difference between them are like the difference between pen and writing.