You have to replace the wire (as you are increasing the current capacity), the outlet, and the breaker. Essentially you have to remove the old circuit and put in a new one. You can't reuse parts of the old circuit as you are increasing the current capacity and they would be underrated.

User Avatar

Wiki User

18y ago

What else can I help you with?

Related Questions

What is 5a³ plus 15a² plus 20a?

It cannot be simplified any further, so it is: 5a³ + 15a² + 20a


Missing fuse diagram can someone list the colors or fuses?

The fuse diagram for my 91 Capri is as fallows: Engine 15A Stop 20A Power Window 30A \ Meter 10A Hazard 15A ------ HTD B-light 20A Cigar 15A Tail 15A IG Relay Room 10A door lock 30A Audio 15A \ Fog Lamp 20A Air Cond 15A ----- \ Cooling Fan 20A Wiper 20A Heater 30A The IG Relay and the Heater are the big ones on the side of the fuse box.


Can I safely install a 20A outlet on a 15A circuit?

No, it is not safe to install a 20A outlet on a 15A circuit. The outlet should match the circuit's amperage to prevent overloading and potential fire hazards.


Is it safe to install a 15A outlet on a 20A circuit?

No, it is not safe to install a 15A outlet on a 20A circuit. The outlet should match the circuit's amperage to prevent overheating and potential fire hazards.


What size is a fuse on a 350 warrior?

Stock fuses are usually 15a, but I use a 20a.


Are 15a receptacles ul rated for 20a?

The kitchen and garage are the only 20 amp circuts usually.


How do you wire a 240V 60Hz 20A convection oven?

two hot one ground


Can a 30A 240V outlet be replaced by a 20A 240V one?

You can, but be advised that whatever you plug into the new outlet should not exceed 5000W capacity (20A x 250V = 5000W)or you could risk overheating the new outlet with serious results. To prevent this, you should make sure the circuit breaker is a 20A also.


Would a 30A 240V circuit breaker be too large to safely support a either a 20A or 23A 240V bandsaw?

Yes it will operate it fine.


What is the right circuit break to be used for lighting circuits?

Usually 15A or 20A, but it depends on the wire used.


What is the max wattage for a 120V outlet?

Power [Watts] = Voltage [Volts] * Current [Amps] These equations assume purely resistive loads, all in the ideal format, anything other than ideal will vary based on your homes wiring, the types of breakers that you use, the type of device [load] that you put on the circuit, etc. For a 20A Circuit: 120V (RMS) * 20A = 2400W (Keep in mind that this is an ideal case) For a 15A Circuit: 120V (RMS) * 15A = 1800W (Keep in mind that this is an ideal case)


Does the NEC code allow multiple 20A receptacles on a 20A circuit Put another way does a 20A receptacle with T shaped neutral slots imply that no other outlets are that circuit?

The National Electrical Code (US) allows up to thirteen 20 amp receptacles on a 20 amp circuit. 120V x 20A = 2400 VA each duplex receptacle is calculated at 180 VA 2400 / 180 = 13.3333 receptacles, since you can't put a third of a receptacle in, you have to round down to 13.