Pegging steam is used to create a scrubbing action between the steam and the feedwater, by which we can eliminate the dissolved corrosive gases mainly O2, CCO2, and NH3 which becomes corrosive at elevated temperatures. The removal of these gases is necessary to protect the piping and associated equipments. The gases removed are vented out of the deaerator to atmosphere
Based on practical experience, deaerator manufacturers will aim to vent 22,4 kg / h of steam/air mixture per 1.000 kg / h of deaerator capacity.
what really is regenerative and pegging inventory
deaerator is a device used to remove dissolved oxygen and carbondi oxide in boiler feed water. it causes scaling inside the boiler tubes and economizer also.
to develop NPSH in BFP
to remove the oxygen and carbon di oxide in boiler feed water we are the various deaerator mechanical deaerator spry typr vaccum type likr thwt
By putting deaerator at height, vapour doesn't form at the suction area of feed water pumps so cavitation phenomenon in the impeller can be prevented. also to get NPSH.
8 points.
by pegging
A deaerator device is a mechanism found on steam boilers. Its purpose is to remove oxygen and other gases from the water that is entering the boiler tank, since the presence of oxygen or gases can cause corrosion on the inside of the boiler.
By getting a miner's licence and pegging out a claim.
deaerator
When you secure a tent to the ground to stop it from blowing away with tent pegs.