Q: What size evaporator will work a 2 ton condenser?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can you install a 3.5 ton condenser on a 3 ton evaporator?

Installing a 3 1/2 ton condenser on a 3 tr evaporator will not function properly. There isn't enough evaporator coil surface area to absorb heat and vaporize refrigerant liquid for its return back to the condenser compressor. What can be done is a 3 ton condenser unit with a 3 1/2 evaporator coil.


Can a 3.5 ton evaporator be used with a 4 ton condenser?

yes it can. you can you can only downsize a coil by .5 tons or up .the flowrator piston have to be be changed according the the condenser size don't ever try to go more than1/2 ton it would damage the system.


Can a 4 ton evaporator be used with a 3.5 ton condenser?

yes it can. you can you can only downsize a coil by .5 tons or up .the flowrator piston have to be be changed according the the condenser size don't ever try to go more than1/2 ton it would damage the system.


What ton unit should you have inside if you have a 4 ton ac outside?

It depends on the cooling load for the home. air conditioners are sized and rated as a matched system consisting of the condenser and evaporator. The capacity of the system changes with the different evaporators. Usually you use either the same size as the condenser or 1/2 ton larger.


Can use 7 ton condenser unit hook up the 6 ton evaporator?

you can probably get away with that just make sure you have an expansion valve on the evaporator. An expansion valve will keep liquid from getting back to the compressor.


Do you have to have a 4 ton coil for a 4 ton ac unit?

The rating is technically a minimum. You could use a larger coil and have it work. But if its a Evaporator coil it will need to be matched on the far end with a similar or larger condenser coil. If the Condenser coil is larger it will probably just take a little more refrigerant.


Can you match 3.5 ton condenser with 3 ton air handler?

You can not do that. If it where the opposite it would work . But you will frezze up with this matchup.


Can a 3 ton coil work with a 2 ton condenser?

Yes it will. Typically a coil is sized a 1/2 ton larger than the a/c out side for efficiency, but a whole ton bigger should still work


Can 3 ton a coil work with a 2 ton condenser?

Yes it will. Typically a coil is sized a 1/2 ton larger than the a/c out side for efficiency, but a whole ton bigger should still work


What size ac condenser unit is needed for 1500 sq ft house?

4 ton


How do you remove the interior air conditioner condenser on a 1998 Chrysler Town and Country?

To start, the inside is the evaporator, the outside in front of the radiator is the condenser. It involves four hours or better to do it .You need to roll back the instrument panel to get to the evaporator housing then that comes out. A ton of screws and parts need to be removed, one of the most dreaded jobs that I had to do as a Chrysler tech. Glad I retired. tsw


What size condensor for 1800 square foot home?

A condenser is typically installed based on 400 square feet per (1) ton. That is, in a dwelling of 1800 square feet, a 4 & 1/2 ton unit, (for air conditioning), will be needed. Any less and the condenser will have to work too hard. Much more and the condenser will over work, (due to start-up and cool down energy overlapping, as well as the excess energy required to run the larger unit), thereby wasting money.