Yes it will. Typically a coil is sized a 1/2 ton larger than the a/c out side for efficiency, but a whole ton bigger should still work
Level Up - 2012 Blast-a-ton 2-0 1-9 was released on: USA: 3 April 2012
No, it's not necessarily a blown voice coil. I am actually going through this right now. I found 2 months ago that suggested I take the woofer out of the box and look at it and inspect it. Sure enough, I noticed 1 tiny wire separated in an awkward spot beneath the woofer. I believe by re-attaching this wire the problem will be corrected, mind you I had the same problem as far as pushing it in.
The Great Khali - 7'3 420 lbs. the strongest is the big show he tip over an over 2 ton jeep
2 days
4Some - 2012 Work on This 1-2 was released on: USA: 8 November 2012 (internet)
Yes it will. Typically a coil is sized a 1/2 ton larger than the a/c out side for efficiency, but a whole ton bigger should still work
Installing a 3 1/2 ton condenser on a 3 tr evaporator will not function properly. There isn't enough evaporator coil surface area to absorb heat and vaporize refrigerant liquid for its return back to the condenser compressor. What can be done is a 3 ton condenser unit with a 3 1/2 evaporator coil.
1.5 ton evaporator
yes it can. you can you can only downsize a coil by .5 tons or up .the flowrator piston have to be be changed according the the condenser size don't ever try to go more than1/2 ton it would damage the system.
yes it can. you can you can only downsize a coil by .5 tons or up .the flowrator piston have to be be changed according the the condenser size don't ever try to go more than1/2 ton it would damage the system.
It is not recommended to mix a 2 ton coil with a 2.5 ton compressor as it may lead to inefficiencies and potential system failures. It is best to match the coil and compressor sizes to ensure optimal performance and efficiency of the HVAC system.
That depends on 1) what indoor coil you have, 2) is the ductwork adequate to support 4 tons and 3) if the indoor coil and ductwork are suitable does the blower have the capacity to support 4 tons or 1600 cfm? If so it must be sped up.
2
Maybe. The coil is not matched to a 2 or 3 ton truck It is matched to the engine and igniton control system. So it may be the same part #.
Between $490-765. That's a range for a 2 ton to 5 ton residential a/c coil cleaning.
I'm not an air conditioning expert, but I would expect that the compressor will run a lot more than it needs to. A 2 ton coil will not cool as much air as a larger capacity 3 ton coil. Experts?
A 2-ton air conditioner typically contains around 4-5 pounds of R22 refrigerant.